Transient Synchronization Stability Analysis and Assessment of DFIG System Under Severe Faults

In the transient stability analysis of renewable energy grid-tied systems, although a large amount of works have been devoted to the detailed electromagnetic transient simulation and the stability analyses of during-fault stage, the whole low-voltage ride through (LVRT) process and transient stability mechanism remain to be uncovered. Taking the doubly fed induction generator system as an objective, this paper divides its transient processes into four different stages, including the pre-fault, during-fault, early post-fault, and late post-fault ones, establishes the full mechanism models for each stage, and studies the sequential switching dynamics in detail. It is found that the during-fault dynamics can be determined by the phase-lock loop second-order equation within the framework of the generalized swing equation (GSE), with additive scaled parameters. In particular, for the early post-fault stage dynamics, it can be treated as a series of quasi-steady states and its dominant driving system dynamics can still be described by the GSE. Thus the system transient stability can be completely determined by whether the initial state of the early post-fault stage is within or out of its corresponding basin of attraction (BOA). Based on these unique dynamical characteristics, the BOA-based and equal area criterion (EAC)-based transient stability assessment methods are developed, which are supported by broad numerical simulations and hardware-in-the-loop experiments. This work provides a clear physical picture and perfectly solves the difficult stability analysis problem when severe faults and LVRT showing discontinuous switching dynamics have to be considered in most of DFIG engineering situations.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Electronics
Published
2025-09-02
DOI
https://doi.org/10.1109/tpel.2025.3605030
Citations
1
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.53
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transient Synchronization Stability Analysis and Assessment of DFIG System Under Severe Faults

Meng Zhan, Han Xu
1 citations
IEEE Transactions on Power Electronics
Power Systems and Renewable Energy
0.53
article

Transient Synchronization Stability Analysis and Assessment of DFIG System Under Severe Faults

Meng Zhan, Han Xu
article en
1 citations

Abstract

In the transient stability analysis of renewable energy grid-tied systems, although a large amount of works have been devoted to the detailed electromagnetic transient simulation and the stability analyses of during-fault stage, the whole low-voltage ride through (LVRT) process and transient stability mechanism remain to be uncovered. Taking the doubly fed induction generator system as an objective, this paper divides its transient processes into four different stages, including the pre-fault, during-fault, early post-fault, and late post-fault ones, establishes the full mechanism models for each stage, and studies the sequential switching dynamics in detail. It is found that the during-fault dynamics can be determined by the phase-lock loop second-order equation within the framework of the generalized swing equation (GSE), with additive scaled parameters. In particular, for the early post-fault stage dynamics, it can be treated as a series of quasi-steady states and its dominant driving system dynamics can still be described by the GSE. Thus the system transient stability can be completely determined by whether the initial state of the early post-fault stage is within or out of its corresponding basin of attraction (BOA). Based on these unique dynamical characteristics, the BOA-based and equal area criterion (EAC)-based transient stability assessment methods are developed, which are supported by broad numerical simulations and hardware-in-the-loop experiments. This work provides a clear physical picture and perfectly solves the difficult stability analysis problem when severe faults and LVRT showing discontinuous switching dynamics have to be considered in most of DFIG engineering situations.

IEEE Transactions on Power ElectronicsVol. 41(3)
Huazhong University of Science and Technology (CN)
Openalex Percentile: Top 27%
Power Systems and Renewable Energy
0.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Transient Synchronization Stability Analysis and Assessment of DFIG System Under Severe Faults — Meng Zhan, Han Xu · IEEE Transactions on Power Electronics (2025) | TGRS Research Map | TGRS