Analysis of Freezing of Gait in Parkinson’s Disease Detection Using a Multimodal Prototype Learning Framework

Patients with severe Parkinson's disease (PD) frequently have freezing of gait (FOG), a gait disability. By anticipating FOG before it occurs, pre-emptive cueing can either prevent FOG or lessen its severity and duration. To improve the accuracy of FOG detection, both electroencephalography (EEG) data and other complementary modalities, such as gait-based data, are increasingly being explored. The use of multimodal data is particularly important, as it enhances the robustness and accuracy of the detection models by combining different perspectives of the disease. Deep learning algorithms got a lot of attention in recent years for automated FOG identification; however their usefulness has been restricted due to a shortage of data samples, particularly medical data such as EEG. The scarcity of data can lead to overfitting in deep learning models, making it crucial for researchers to develop robust classification models that can operate effectively with a limited number of samples. Few-shot learning methods, such as prototype learning, have been introduced to mitigate these challenges by enabling models to effectively learn from a modest number of labeled samples. Thus in this research, we propose a prototype learning framework called CSE-ProtoNet, which utilizes CondenseNet with SEBlock for FOG detection in PD patients. Importantly, our study will leverage not only EEG data but also multimodal inputs, which can enhance the robustness and accuracy of PD detection. The method outperforms baseline models such as CSE-ProtoNet-ED, ProtoNet-CS, and ProtoNet-ED in terms of accuracy, F-score, recall, specificity, precision and AUC. The CSE-ProtoNet model also differentiated patients with FOG and Non-FOG with an accuracy of 98.75%. Cross-data validation was conducted to ensure the robustness and generalizability of the proposed method, confirming consistent performance across different folds.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2025-01-01
DOI
https://doi.org/10.1109/tnsre.2025.3605204
Primary Topic
Hand Gesture Recognition Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Freezing of Gait in Parkinson’s Disease Detection Using a Multimodal Prototype Learning Framework

Ananda Rao Akepogu, P. Radhika Raju, Madhuri Thimmapuram
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Hand Gesture Recognition Systems
article

Analysis of Freezing of Gait in Parkinson’s Disease Detection Using a Multimodal Prototype Learning Framework

Ananda Rao Akepogu, P. Radhika Raju, Madhuri Thimmapuram
article en

Abstract

Patients with severe Parkinson's disease (PD) frequently have freezing of gait (FOG), a gait disability. By anticipating FOG before it occurs, pre-emptive cueing can either prevent FOG or lessen its severity and duration. To improve the accuracy of FOG detection, both electroencephalography (EEG) data and other complementary modalities, such as gait-based data, are increasingly being explored. The use of multimodal data is particularly important, as it enhances the robustness and accuracy of the detection models by combining different perspectives of the disease. Deep learning algorithms got a lot of attention in recent years for automated FOG identification; however their usefulness has been restricted due to a shortage of data samples, particularly medical data such as EEG. The scarcity of data can lead to overfitting in deep learning models, making it crucial for researchers to develop robust classification models that can operate effectively with a limited number of samples. Few-shot learning methods, such as prototype learning, have been introduced to mitigate these challenges by enabling models to effectively learn from a modest number of labeled samples. Thus in this research, we propose a prototype learning framework called CSE-ProtoNet, which utilizes CondenseNet with SEBlock for FOG detection in PD patients. Importantly, our study will leverage not only EEG data but also multimodal inputs, which can enhance the robustness and accuracy of PD detection. The method outperforms baseline models such as CSE-ProtoNet-ED, ProtoNet-CS, and ProtoNet-ED in terms of accuracy, F-score, recall, specificity, precision and AUC. The CSE-ProtoNet model also differentiated patients with FOG and Non-FOG with an accuracy of 98.75%. Cross-data validation was conducted to ensure the robustness and generalizability of the proposed method, confirming consistent performance across different folds.

IEEE Transactions on Neural Systems and Rehabilitation EngineeringVol. 33
Jawaharlal Nehru Technological University Anantapur (IN)
Openalex Percentile: Top 77%
Hand Gesture Recognition Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.