Impact of high-concentration office-type bleaching agent on physical properties of different types of bulk-fill composites

This study investigated the effect of a 45% carbamide peroxide-containing office-type bleaching agent on the microhardness (MH) and surface roughness (SR) of flowable and paste-type bulk-fill composite resins. This study used two bulk-fill composite resins, 3 M Filtek Bulk-Fill (paste) and Estelite Bulk-Fill Flow (flowable). Twenty disc-shaped specimens were prepared and divided into two groups according to the type of bulk-fill materials. All samples were stored at room temperature for 24 h with artificial saliva. Initial MH and surface SR values were measured. High-concentration office-type (HCOT) bleaching agent was applied to the samples for 30 min, and then the same procedure was repeated after one week. Following completion of bleaching procedures, final MH and surface SR values were evaluated. The MH values were analyzed by ANOVA and Kruskal-Wallis tests was used for SR values with a significance of 0.05. A statistically significant difference was found between the MH values of the groups before and after bleaching (p = .002). SR value of 3 M Filtek Bulk-Fill was found statistically higher than Estelite Bulk-Fill Flow after or before bleaching treatment. Statistically significant difference was found SR value of 3 M Filtek Bulk-Fill when compared to before and after bleaching procedures (p = .024). Bleaching with high-concentration office-type material significantly reduced the MH of both bulk-fill composites. While HCOT was applied, Estelite Bulk-Fill Flow did not cause a significant change in surface SR. In contrast, the SR value of 3 M Filtek Bulk-Fill was statistically higher. Therefore, if bleaching with a high-concentration office-type bleaching material is planned, it is recommended not to use 3 M Filtek Bulk-Fill as a restorative material, or it may be recommended to renew existing composite resin restorations after bleaching treatment.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2025-09-02
DOI
https://doi.org/10.1186/s12903-025-06723-7
Primary Topic
Dental Erosion and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of high-concentration office-type bleaching agent on physical properties of different types of bulk-fill composites

Bugra Duc, Nazmiye Dönmez, Mağrur Kazak, Zeynep Buket Kaynar
BMC Oral Health
Dental Erosion and Treatment
article

Impact of high-concentration office-type bleaching agent on physical properties of different types of bulk-fill composites

Bugra Duc, Nazmiye Dönmez, Mağrur Kazak, Zeynep Buket Kaynar
article en

Abstract

This study investigated the effect of a 45% carbamide peroxide-containing office-type bleaching agent on the microhardness (MH) and surface roughness (SR) of flowable and paste-type bulk-fill composite resins. This study used two bulk-fill composite resins, 3 M Filtek Bulk-Fill (paste) and Estelite Bulk-Fill Flow (flowable). Twenty disc-shaped specimens were prepared and divided into two groups according to the type of bulk-fill materials. All samples were stored at room temperature for 24 h with artificial saliva. Initial MH and surface SR values were measured. High-concentration office-type (HCOT) bleaching agent was applied to the samples for 30 min, and then the same procedure was repeated after one week. Following completion of bleaching procedures, final MH and surface SR values were evaluated. The MH values were analyzed by ANOVA and Kruskal-Wallis tests was used for SR values with a significance of 0.05. A statistically significant difference was found between the MH values of the groups before and after bleaching (p = .002). SR value of 3 M Filtek Bulk-Fill was found statistically higher than Estelite Bulk-Fill Flow after or before bleaching treatment. Statistically significant difference was found SR value of 3 M Filtek Bulk-Fill when compared to before and after bleaching procedures (p = .024). Bleaching with high-concentration office-type material significantly reduced the MH of both bulk-fill composites. While HCOT was applied, Estelite Bulk-Fill Flow did not cause a significant change in surface SR. In contrast, the SR value of 3 M Filtek Bulk-Fill was statistically higher. Therefore, if bleaching with a high-concentration office-type bleaching material is planned, it is recommended not to use 3 M Filtek Bulk-Fill as a restorative material, or it may be recommended to renew existing composite resin restorations after bleaching treatment.

BMC Oral HealthVol. 25(1)
Bahçeşehir University (TR), Istanbul Medipol University (TR), Bolu Abant İzzet Baysal University (TR), Okan University (TR)
Openalex Percentile: Top 76%
Dental Erosion and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.