Evaluation of VIABAHN<sup>®</sup> Endoprosthesis for Thoracic, Abdominal, and Pelvic Artery Injuries

<b>Purpose:</b> To evaluate the efficacy and safety of the GORE<sup>Ⓡ</sup> VIABAHN<sup>Ⓡ</sup> Endoprosthesis (stent graft) for traumatic or iatrogenic vessel injury. <b>Material and Methods:</b> This prospective, multicenter, cohort study for post-marketing clinical surveillance was conducted in Japan. Efficacy and safety endpoints included successful device implantation, primary and secondary hemostasis of injury, 1-month and 1-year survival rate, and at 1-, 6-, 12-months post-procedure, primary and secondary patency rates, antiplatelet drug administration, and serious adverse events. <b>Results:</b> In 37 patients (mean age 73.3±12.5 years; 22 males; 59.5%), 38 vessel injuries were evaluated. Primary treated arteries were visceral, subclavian, and iliac arteries; 86.8% (33/38) were iatrogenic, and 13.2% (5/38) were traumatic vessel injury. Iatrogenic injury included pseudoaneurysm (63.6%), perforation (24.4%), rupture (15.2%), dissection (12.1%), or fistula (3.0%). Technical success in 36 patients (36/37; 97.3%) with 37 vessels (37/38; 97.4%), and primary and secondary hemostasis in all patients were achieved. Primary patency at 1-, 6-, and 12-months was 89.1%, 84.8%, and 80.6%, and secondary patency was 91.5%, 87.3%, and 82.4%, respectively. The Kaplan-Meier survival estimate was 94.4% through 1 month and 75.9% through 1 year. No device-related deaths occurred. Through 12 months, of the 19 serious adverse events (13 patients), three serious adverse events were judged by the investigator to be device-related (vascular stent graft stenosis) or procedure-related (device occlusion and cerebellar infarction). <b>Conclusions:</b> The use of the VIABAHN stent graft for vessel injury was safe and effective in this study. Successful hemostasis was achieved through 1 month. Through 1 year, no device-related deaths were reported.

Authors

Institutions

Publication Details

Journal
Interventional Radiology
Published
2025-09-02
DOI
https://doi.org/10.22575/interventionalradiology.2024-0038
Primary Topic
Trauma Management and Diagnosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of VIABAHN® Endoprosthesis for Thoracic, Abdominal, and Pelvic Artery Injuries

Kimihiko Kichikawa, Hiroyuki Tajima, Daisuke Abo, Hiroshi Anai et al.
Interventional Radiology
Trauma Management and Diagnosis
article

Evaluation of VIABAHN® Endoprosthesis for Thoracic, Abdominal, and Pelvic Artery Injuries

Kimihiko Kichikawa, Hiroyuki Tajima, Daisuke Abo, Hiroshi Anai, Yasutaka Baba, Osamu Ikeda, Toshihiro Tanaka, Toyohiro Ota, Hideyuki Nishiofuku
article en

Abstract

<b>Purpose:</b> To evaluate the efficacy and safety of the GORE<sup>Ⓡ</sup> VIABAHN<sup>Ⓡ</sup> Endoprosthesis (stent graft) for traumatic or iatrogenic vessel injury. <b>Material and Methods:</b> This prospective, multicenter, cohort study for post-marketing clinical surveillance was conducted in Japan. Efficacy and safety endpoints included successful device implantation, primary and secondary hemostasis of injury, 1-month and 1-year survival rate, and at 1-, 6-, 12-months post-procedure, primary and secondary patency rates, antiplatelet drug administration, and serious adverse events. <b>Results:</b> In 37 patients (mean age 73.3±12.5 years; 22 males; 59.5%), 38 vessel injuries were evaluated. Primary treated arteries were visceral, subclavian, and iliac arteries; 86.8% (33/38) were iatrogenic, and 13.2% (5/38) were traumatic vessel injury. Iatrogenic injury included pseudoaneurysm (63.6%), perforation (24.4%), rupture (15.2%), dissection (12.1%), or fistula (3.0%). Technical success in 36 patients (36/37; 97.3%) with 37 vessels (37/38; 97.4%), and primary and secondary hemostasis in all patients were achieved. Primary patency at 1-, 6-, and 12-months was 89.1%, 84.8%, and 80.6%, and secondary patency was 91.5%, 87.3%, and 82.4%, respectively. The Kaplan-Meier survival estimate was 94.4% through 1 month and 75.9% through 1 year. No device-related deaths occurred. Through 12 months, of the 19 serious adverse events (13 patients), three serious adverse events were judged by the investigator to be device-related (vascular stent graft stenosis) or procedure-related (device occlusion and cerebellar infarction). <b>Conclusions:</b> The use of the VIABAHN stent graft for vessel injury was safe and effective in this study. Successful hemostasis was achieved through 1 month. Through 1 year, no device-related deaths were reported.

Interventional RadiologyVol. 10(0)
Aichi Medical University (JP), Nara City Hospital (JP), Kumamoto University Hospital (JP), Hokkaido University Hospital (JP), Nara Medical University (JP), Saitama Medical University (JP), Kumamoto University (JP)
Openalex Percentile: Top 63%
Trauma Management and Diagnosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.