Interfacial Water Dielectric Constant in the Parallel Direction to Its Surface: A Measuring Technique

The dielectric constant of interfacial water was recently measured in the normal direction to the water surface; this study showed a significant reduction to a value as low as ε ∼3. Here, a technique that measures parallel to the water surface dielectric constant is described. An asymmetric arrangement of electrodes results in a configuration in which surface and bulk charging effects are separated. The water surface is responsible for the initial fast charge rearrangement. Parallel to the water surface, values as low as ε ≈ 35-40 were measured in agreement with models that show that this ∼50% reduction is associated with the interfacial water confined structure.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2025-09-02
DOI
https://doi.org/10.1021/acsomega.5c05531
Citations
1
Primary Topic
Electrostatics and Colloid Interactions
Type
article
Field-Weighted Citation Impact
1.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interfacial Water Dielectric Constant in the Parallel Direction to Its Surface: A Measuring Technique

O. Teschke, David Mendez Soares, Wyllerson Evaristo Gomes
1 citations
ACS Omega
Electrostatics and Colloid Interactions
1.75
article

Interfacial Water Dielectric Constant in the Parallel Direction to Its Surface: A Measuring Technique

O. Teschke, David Mendez Soares, Wyllerson Evaristo Gomes
article en
1 citations

Abstract

The dielectric constant of interfacial water was recently measured in the normal direction to the water surface; this study showed a significant reduction to a value as low as ε ∼3. Here, a technique that measures parallel to the water surface dielectric constant is described. An asymmetric arrangement of electrodes results in a configuration in which surface and bulk charging effects are separated. The water surface is responsible for the initial fast charge rearrangement. Parallel to the water surface, values as low as ε ≈ 35-40 were measured in agreement with models that show that this ∼50% reduction is associated with the interfacial water confined structure.

ACS OmegaVol. 10(36)
Universidade Estadual de Campinas (UNICAMP) (BR), User Interface Design (Germany) (DE), Rede de Química e Tecnologia (PT), Hospital de Clínicas da Unicamp (BR), Pontifícia Universidade Católica de Campinas (BR)
Openalex Percentile: Top 13%
Electrostatics and Colloid Interactions
1.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.