Mathematical deviation analysis of characteristic performance points of the turbine condenser pump after bypass modification

This article presents a detailed mathematical deviation analysis of the characteristic performance points of a turbine condenser pump following a bypass system modification. The primary task of the turbine condenser pump is to pump condensate from the condenser into the boiler feedwater system. Additionally, the condensate from the condenser pump serves as cooling water for auxiliary systems, such as ejector system cooling and steam dump device cooling. The condenser pump must operate within its characteristic performance properties to ensure the appropriate flow and pressure required for the uninterrupted operation of these systems. The bypass system, which is essential for directing steam during the start-up and trip of the steam turbine, was modified to improve operational flexibility and reliability. To determine the reliability of the condenser pump after the modification, reliability measurements were performed. The reliability was assessed by comparing the characteristic performance points provided by the manufacturer with the measured characteristic points. These measurements were conducted under both atmospheric and vacuum conditions in the turbine condenser. The results indicate that the deviations between the characteristic performance properties specified by the manufacturer and those measured are negligibly small. Minor deviations due to changes in pressure conditions are reflected in the net positive suction head (NPSH) of the condenser pump, and measurements show that operation with an NPSH greater than 1.5 m remains safe. The remaining deviations in characteristic performance properties are within acceptable limits, amounting to up to 3 %. Overall, the results reveal that the bypass modification does not adversely affect pump performance, and the observed shifts in characteristic performance curves are within tolerable operational limits, ensuring continued reliability and stability of the condenser system. • The reliability measurements of the condenser pump after the bypass modification were performed. • These measurements were conducted under both atmospheric and vacuum conditions in the turbine condenser. • The deviations between the characteristic properties specified by the manufacturer and those measured are negligibly small. • Minor deviations due to changes in pressure conditions are reflected in the net positive suction head and.

Authors

Institutions

Publication Details

Journal
Flow Measurement and Instrumentation
Published
2025-08-27
DOI
https://doi.org/10.1016/j.flowmeasinst.2025.103041
Primary Topic
Advanced Power Generation Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mathematical deviation analysis of characteristic performance points of the turbine condenser pump after bypass modification

Jurij Avsec, Dušan Strušnik
5 links
Flow Measurement and Instrumentation
Advanced Power Generation Technologies
article

Mathematical deviation analysis of characteristic performance points of the turbine condenser pump after bypass modification

Jurij Avsec, Dušan Strušnik
article en

Abstract

This article presents a detailed mathematical deviation analysis of the characteristic performance points of a turbine condenser pump following a bypass system modification. The primary task of the turbine condenser pump is to pump condensate from the condenser into the boiler feedwater system. Additionally, the condensate from the condenser pump serves as cooling water for auxiliary systems, such as ejector system cooling and steam dump device cooling. The condenser pump must operate within its characteristic performance properties to ensure the appropriate flow and pressure required for the uninterrupted operation of these systems. The bypass system, which is essential for directing steam during the start-up and trip of the steam turbine, was modified to improve operational flexibility and reliability. To determine the reliability of the condenser pump after the modification, reliability measurements were performed. The reliability was assessed by comparing the characteristic performance points provided by the manufacturer with the measured characteristic points. These measurements were conducted under both atmospheric and vacuum conditions in the turbine condenser. The results indicate that the deviations between the characteristic performance properties specified by the manufacturer and those measured are negligibly small. Minor deviations due to changes in pressure conditions are reflected in the net positive suction head (NPSH) of the condenser pump, and measurements show that operation with an NPSH greater than 1.5 m remains safe. The remaining deviations in characteristic performance properties are within acceptable limits, amounting to up to 3 %. Overall, the results reveal that the bypass modification does not adversely affect pump performance, and the observed shifts in characteristic performance curves are within tolerable operational limits, ensuring continued reliability and stability of the condenser system. • The reliability measurements of the condenser pump after the bypass modification were performed. • These measurements were conducted under both atmospheric and vacuum conditions in the turbine condenser. • The deviations between the characteristic properties specified by the manufacturer and those measured are negligibly small. • Minor deviations due to changes in pressure conditions are reflected in the net positive suction head and.

Flow Measurement and InstrumentationVol. 107
University of Maribor (SI), Informatizacija Energetika Avtomatizacija (Slovenia) (SI)
Openalex Percentile: Top 78%
Advanced Power Generation Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.