Efficacy and safety of 10F percutaneous catheter versus 28F chest tube in pneumothorax: A retrospective comparative study

Aim: Percutaneous catheter drainage has emerged as a less invasive alternative to traditional large-bore chest tubes in the management of pneumothorax.This study aimed to compare the clinical outcomes of 10F percutaneous catheters with 28F chest tubes.Materials and Methods: A retrospective analysis was conducted on 78 patients treated for pneumothorax between May 2023 and May 2025.Patients were divided into two groups: those treated with a 10F percutaneous catheter (n=40) and those treated with a 28F chest tube (n=38).Demographics, pneumothorax etiology, length of hospital stay, drainage duration, prolonged air leak, and need for video-assisted thoracoscopic surgery (VATS) were evaluated.Statistical analyses included Mann-Whitney U, Fisher's exact, and Chi-square tests with Monte Carlo simulation where appropriate.Results: There were no significant differences between groups in age (p=0.1596),sex (p=0.1406),pneumothorax side (p=0.4383), or COPD prevalence (p=0.9382).Etiological distribution showed a statistically significant difference (p=0.0051);notably, 10F catheters were not utilized in cases of penetrating trauma.Mean hospital stay and drainage duration were not significantly different between groups (p=0.0656 and p=0.2709, respectively).The rates of prolonged air leak (p=0.3493) and VATS requirement (p=0.9495) were also similar.Discussion: The 10F percutaneous catheter demonstrated comparable efficacy and safety to the conventional 28F chest tube in the management of pneumothorax.Despite being less invasive, it yielded similar clinical outcomes, supporting its use as a safe and effective alternative for treating spontaneous pneumothorax and blunt trauma cases.

Authors

Institutions

Publication Details

Journal
The Annals of Clinical and Analytical Medicine
Published
2025-01-01
DOI
https://doi.org/10.4328/acam.22800
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacy and safety of 10F percutaneous catheter versus 28F chest tube in pneumothorax: A retrospective comparative study

İsmail Dal
1 links
The Annals of Clinical and Analytical Medicine
Airway Management and Intubation Techniques
article

Efficacy and safety of 10F percutaneous catheter versus 28F chest tube in pneumothorax: A retrospective comparative study

İsmail Dal
article en

Abstract

Aim: Percutaneous catheter drainage has emerged as a less invasive alternative to traditional large-bore chest tubes in the management of pneumothorax.This study aimed to compare the clinical outcomes of 10F percutaneous catheters with 28F chest tubes.Materials and Methods: A retrospective analysis was conducted on 78 patients treated for pneumothorax between May 2023 and May 2025.Patients were divided into two groups: those treated with a 10F percutaneous catheter (n=40) and those treated with a 28F chest tube (n=38).Demographics, pneumothorax etiology, length of hospital stay, drainage duration, prolonged air leak, and need for video-assisted thoracoscopic surgery (VATS) were evaluated.Statistical analyses included Mann-Whitney U, Fisher's exact, and Chi-square tests with Monte Carlo simulation where appropriate.Results: There were no significant differences between groups in age (p=0.1596),sex (p=0.1406),pneumothorax side (p=0.4383), or COPD prevalence (p=0.9382).Etiological distribution showed a statistically significant difference (p=0.0051);notably, 10F catheters were not utilized in cases of penetrating trauma.Mean hospital stay and drainage duration were not significantly different between groups (p=0.0656 and p=0.2709, respectively).The rates of prolonged air leak (p=0.3493) and VATS requirement (p=0.9495) were also similar.Discussion: The 10F percutaneous catheter demonstrated comparable efficacy and safety to the conventional 28F chest tube in the management of pneumothorax.Despite being less invasive, it yielded similar clinical outcomes, supporting its use as a safe and effective alternative for treating spontaneous pneumothorax and blunt trauma cases.

The Annals of Clinical and Analytical MedicineVol. 16(09)
Kastamonu University (TR)
Kastamonu Üniversitesi
Openalex Percentile: Top 64%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Efficacy and safety of 10F percutaneous catheter versus 28F chest tube in pneumothorax: A retrospective comparative study — İsmail Dal · The Annals of Clinical and Analytical Medicine (2025) | TGRS Research Map | TGRS