Smart Audit and Monitoring of Transmission Towers (SAMST)

A major power outage hit Montenegro, Bosnia, Albania and most of Croatia's coast in June 2024. Many reports have indicated interconnector breakdowns between Albania and Greece as well as fire catching on a 400 kW transmission line at the border between Bosnia and Montenegro. Localization of failures along the transmission lines is a critical task in cases of power outages. Currently, there is no way of remote pinpointing the location of a fault: the technicians perform the inspection of the area, where the issue has been reported. The larger the reported area, the longer the time needed for localization and repair. This paper aims to propose a Smart Audit and Monitoring System of Transmission Towers (SAMST), based on Long Range Wide Area Network (LoRaWAN) devices. The results of this study indicate the possibility of preventing transmission line faults and shortening the time of reaction in case of outages. Below described method can improve the safety and quality of service of electric transmission systems, minimizing down times and damage costs.

Authors

Institutions

Publication Details

Published
2025-06-02
DOI
https://doi.org/10.1109/mipro65660.2025.11131718
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Smart Audit and Monitoring of Transmission Towers (SAMST)

Milan Maric, Dragan Maric, A. Gualandi
Smart Grid and Power Systems
article

Smart Audit and Monitoring of Transmission Towers (SAMST)

Milan Maric, Dragan Maric, A. Gualandi
article en

Abstract

A major power outage hit Montenegro, Bosnia, Albania and most of Croatia's coast in June 2024. Many reports have indicated interconnector breakdowns between Albania and Greece as well as fire catching on a 400 kW transmission line at the border between Bosnia and Montenegro. Localization of failures along the transmission lines is a critical task in cases of power outages. Currently, there is no way of remote pinpointing the location of a fault: the technicians perform the inspection of the area, where the issue has been reported. The larger the reported area, the longer the time needed for localization and repair. This paper aims to propose a Smart Audit and Monitoring System of Transmission Towers (SAMST), based on Long Range Wide Area Network (LoRaWAN) devices. The results of this study indicate the possibility of preventing transmission line faults and shortening the time of reaction in case of outages. Below described method can improve the safety and quality of service of electric transmission systems, minimizing down times and damage costs.

AstraZeneca (Italy) (IT), University of Montenegro (ME), University of Bologna (IT)
Openalex Percentile: Top 78%
Smart Grid and Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Smart Audit and Monitoring of Transmission Towers (SAMST) — Milan Maric, Dragan Maric, et al. · (2025) | TGRS Research Map | TGRS