Influence of the number of images on threshold image contrast measurements with a phantom with gold disks in digital mammography

Image quality, in addition to radiation dose, is the most important physical parameter in digital mammography. Image quality should be periodically monitored using the CDMAM phantom. The aim of this study is to investigate the effect of the number of analyzed images on the result of threshold image contrast measurements using the CDMAM phantom in different versions. The images obtained using two versions of the CDMAM phantom, i.e., 3.4 and 4.0, were analyzed. The image analysis was performed and repeated 10 times for 2, 4, 6, 8, 12, 16, 24, and 32 images from a pool of 43 images, separately for each phantom. For the CDMAM 3.4 phantom, a statistical difference was demonstrated between the following groups: S2 vs S6 (p < 0.006), S6 vs S16 (p < 0.001), S6 vs S24 (p < 0.002), S6 vs S32 (p < 0.021), S8 vs S16 (p < 0.019), S8 vs S24 (p < 0.048). For the CDMAM 4.0 phantom, a statistically significant difference was demonstrated between all groups and the N2 group (p < 0.000). For the CDMAM 3.4 phantom, the most favorable number of images required for analysis cannot be clearly determined. For the CDMAM 4.0 phantom, it is recommended to perform 24 images for analysis. Particular attention should be paid when determining the threshold image contrast for a disk diameter of 0.1 mm, as this parameter is used during exposure automation control.

Authors

Institutions

Publication Details

Journal
Radiological Physics and Technology
Published
2025-09-02
DOI
https://doi.org/10.1007/s12194-025-00958-3
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of the number of images on threshold image contrast measurements with a phantom with gold disks in digital mammography

Michał Biegała, Agata Batolik
Radiological Physics and Technology
Digital Radiography and Breast Imaging
article

Influence of the number of images on threshold image contrast measurements with a phantom with gold disks in digital mammography

Michał Biegała, Agata Batolik
article en

Abstract

Image quality, in addition to radiation dose, is the most important physical parameter in digital mammography. Image quality should be periodically monitored using the CDMAM phantom. The aim of this study is to investigate the effect of the number of analyzed images on the result of threshold image contrast measurements using the CDMAM phantom in different versions. The images obtained using two versions of the CDMAM phantom, i.e., 3.4 and 4.0, were analyzed. The image analysis was performed and repeated 10 times for 2, 4, 6, 8, 12, 16, 24, and 32 images from a pool of 43 images, separately for each phantom. For the CDMAM 3.4 phantom, a statistical difference was demonstrated between the following groups: S2 vs S6 (p < 0.006), S6 vs S16 (p < 0.001), S6 vs S24 (p < 0.002), S6 vs S32 (p < 0.021), S8 vs S16 (p < 0.019), S8 vs S24 (p < 0.048). For the CDMAM 4.0 phantom, a statistically significant difference was demonstrated between all groups and the N2 group (p < 0.000). For the CDMAM 3.4 phantom, the most favorable number of images required for analysis cannot be clearly determined. For the CDMAM 4.0 phantom, it is recommended to perform 24 images for analysis. Particular attention should be paid when determining the threshold image contrast for a disk diameter of 0.1 mm, as this parameter is used during exposure automation control.

Radiological Physics and TechnologyVol. 18(4)
Copernicus Memorial Hospital (PL), Medical University of Lodz (PL)
Openalex Percentile: Top 66%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence of the number of images on threshold image contrast measurements with a phantom with gold disks in digital mammography — Michał Biegała, Agata Batolik · Radiological Physics and Technology (2025) | TGRS Research Map | TGRS