In-situ simultaneous extraction of non-steroidal anti-inflammatory drugs from wastewater using 3D-printed device and UHPLC-DAD/FLD analysis

Non-steroidal anti-inflammatory drugs (NSAIDs) are widely employed in medicine for their anti-inflammatory and antipyretic properties. Their occurrence has been documented in effluents from wastewater treatment plants (WWTPs), as well as in aquatic ecosystems. NSAIDs are classified as emerging contaminants, thereby underscoring the importance of their environmental monitoring. This study presents a novel approach for the simultaneous on-site extraction of six NSAIDs –acetylsalicylic acid (ASP), celecoxib (CEL), diclofenac (DIC), ibuprofen (IBU), ketoprofen (KET), and naproxen (NAP)– from wastewater, followed by ultra-high performance liquid chromatography coupled with photodiode array and fluorescence detection (UHPLC-DAD/FLD). A 3D-printed device, coated with a highly selective solid-phase extraction (SPE) resin (Oasis HLB®), enabled on-site extraction and preconcentration of the analytes, avoiding to handle large sample volumes. A peristaltic pump helps both retention and elution steps. Method detection limits were 0.12 µg L -1 for ASP, 0.16 µg L -1 for CEL and IBU, 1.5 µg L -1 for DIC, 0.09 µg L -1 for KET and 0.19 µg L -1 for NAP. The analytical performance of the 3D-printed device was demonstrated by precision below 5% and the possibility of reusing up to 24 times without significant loss of extraction efficiency. An AGREEprep score of 0.53 classifies this methodology as moderately green. On-site analysis was conducted at the Calvià WWTP (Mallorca, Spain), where five NSAIDs were detected at various stages, demonstrating the feasibility of the on-site extraction across a broad concentration range. Except for ASP, which exhibited a recovery rate below 47%, the remaining analytes showed satisfactory recoveries, ranging from 90 to 98%.

Authors

Institutions

Publication Details

Journal
Advances in Sample Preparation
Published
2025-09-01
DOI
https://doi.org/10.1016/j.sampre.2025.100210
Citations
1
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In-situ simultaneous extraction of non-steroidal anti-inflammatory drugs from wastewater using 3D-printed device and UHPLC-DAD/FLD analysis

Luz O. Leal, Laura Ferrer, Edwin Palacio, A. Palermo et al.
1 citations
Advances in Sample Preparation
Analytical chemistry methods development
0.75
article

In-situ simultaneous extraction of non-steroidal anti-inflammatory drugs from wastewater using 3D-printed device and UHPLC-DAD/FLD analysis

Luz O. Leal, Laura Ferrer, Edwin Palacio, A. Palermo, César Castro-García
article en
1 citations

Abstract

Non-steroidal anti-inflammatory drugs (NSAIDs) are widely employed in medicine for their anti-inflammatory and antipyretic properties. Their occurrence has been documented in effluents from wastewater treatment plants (WWTPs), as well as in aquatic ecosystems. NSAIDs are classified as emerging contaminants, thereby underscoring the importance of their environmental monitoring. This study presents a novel approach for the simultaneous on-site extraction of six NSAIDs –acetylsalicylic acid (ASP), celecoxib (CEL), diclofenac (DIC), ibuprofen (IBU), ketoprofen (KET), and naproxen (NAP)– from wastewater, followed by ultra-high performance liquid chromatography coupled with photodiode array and fluorescence detection (UHPLC-DAD/FLD). A 3D-printed device, coated with a highly selective solid-phase extraction (SPE) resin (Oasis HLB®), enabled on-site extraction and preconcentration of the analytes, avoiding to handle large sample volumes. A peristaltic pump helps both retention and elution steps. Method detection limits were 0.12 µg L -1 for ASP, 0.16 µg L -1 for CEL and IBU, 1.5 µg L -1 for DIC, 0.09 µg L -1 for KET and 0.19 µg L -1 for NAP. The analytical performance of the 3D-printed device was demonstrated by precision below 5% and the possibility of reusing up to 24 times without significant loss of extraction efficiency. An AGREEprep score of 0.53 classifies this methodology as moderately green. On-site analysis was conducted at the Calvià WWTP (Mallorca, Spain), where five NSAIDs were detected at various stages, demonstrating the feasibility of the on-site extraction across a broad concentration range. Except for ASP, which exhibited a recovery rate below 47%, the remaining analytes showed satisfactory recoveries, ranging from 90 to 98%.

Advances in Sample PreparationVol. 16
Centro de Investigación en Materiales Avanzados (MX), Universitat de les Illes Balears (ES), University of Turin (IT)
Openalex Percentile: Top 27%
Analytical chemistry methods development
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.