Investigation of Experimental and Numerical Study of the Effect of Artificial Roughness on Single‐Pass Solar Air Heater

ABSTRACT An experimental and numerical study has investigated the heat transfer (HT) and friction characteristics of a solar air heater (SAH) duct roughened using a rectangular S‐shaped artificial roughness arrangement (inline and staggered). The thermal performance of SAH is studied with design variables such as the length of the relative roughness ( d/H = 1.33), the height of the relative roughness ( e/H = 0.271), and the distance between S ( b / H = 0.667) remaining constant as the Reynolds number ( Re ) ranges from 3000 to 10,000 and the angle of attack 60°. Relative roughness of pitch range p/H (1.667, 3.33, 5, and 6.667) for inline with relative roughness of length ( l/H ) (0.8335, 1.666, 2.5, and 3.335) for staggered. A three‐dimensional computational fluid dynamics (CFD) simulation is carried out using the CFD code, ANSYS Fluent, and the renormalization group k – ε turbulence model for solving turbulence terms in governing equations. It has been found that HT enhancement can be achieved by using an artificial roughness staggered arrangement at l/H = 0.8335 and e/D = 0.271 with an angle of attack ( α ) of 60°. Also offers the best thermal performance factor for the investigated range of 3.12.

Authors

Institutions

Publication Details

Journal
Heat Transfer
Published
2025-09-02
DOI
https://doi.org/10.1002/htj.70059
Citations
1
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of Experimental and Numerical Study of the Effect of Artificial Roughness on Single‐Pass Solar Air Heater

Ahmed Hashem Yousef, Ghaith Moneem Fadhala
1 citations
Heat Transfer
Heat Transfer Mechanisms
0.71
article

Investigation of Experimental and Numerical Study of the Effect of Artificial Roughness on Single‐Pass Solar Air Heater

Ahmed Hashem Yousef, Ghaith Moneem Fadhala
article en
1 citations

Abstract

ABSTRACT An experimental and numerical study has investigated the heat transfer (HT) and friction characteristics of a solar air heater (SAH) duct roughened using a rectangular S‐shaped artificial roughness arrangement (inline and staggered). The thermal performance of SAH is studied with design variables such as the length of the relative roughness ( d/H = 1.33), the height of the relative roughness ( e/H = 0.271), and the distance between S ( b / H = 0.667) remaining constant as the Reynolds number ( Re ) ranges from 3000 to 10,000 and the angle of attack 60°. Relative roughness of pitch range p/H (1.667, 3.33, 5, and 6.667) for inline with relative roughness of length ( l/H ) (0.8335, 1.666, 2.5, and 3.335) for staggered. A three‐dimensional computational fluid dynamics (CFD) simulation is carried out using the CFD code, ANSYS Fluent, and the renormalization group k – ε turbulence model for solving turbulence terms in governing equations. It has been found that HT enhancement can be achieved by using an artificial roughness staggered arrangement at l/H = 0.8335 and e/D = 0.271 with an angle of attack ( α ) of 60°. Also offers the best thermal performance factor for the investigated range of 3.12.

Heat TransferVol. 54(8)
Al-Furat Al-Awsat Technical University (IQ)
Openalex Percentile: Top 28%
Heat Transfer Mechanisms
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.