Hierarchical Bayesian detection of impulses in Tainter valve machinery systems under uncertainty

Reliable lock operation is crucial for uninterrupted waterway traffic, but failures in fill/empty Tainter valves can hinder lock management. To address this, an in-service lock was instrumented with an array of sensors spanning the motor to the final gear shaft. Unexpected impulses were observed in the jack shaft and sector gear bearing block accelerometer signals during certain valve opening events, coinciding with anomalies in sector gear angular displacement signals. To detect these impulses, a single-channel hierarchical Bayesian framework was employed, utilizing sector gear bearing block acceleration signals. A binary hierarchical Bayesian hypothesis testing approach was developed, assuming Gaussian noise versus Gaussian-distributed signals conditioned on the mean and standard deviation (STD) of the impulses. Unlike traditional Bayesian detection methods that pool all datasets/events together or analyze single events/datasets in isolation, this approach captures aleatory and epistemic uncertainties by modeling the impulse signal mean and dispersion as random variables (RVs). The relationships among different detection models (Neyman–Pearson detection, matched filter, Bayesian detection, and hierarchical Bayesian detection) are mathematically demonstrated, showing how they are interconnected. To address signal non-stationarity within events and signal magnitude across multiple events, optimal windowing and signal normalization were applied to ensure statistical reliability and computational efficiency. A local sensitivity analysis was performed to determine the effect of the decision threshold in this binary hypothesis testing to the hyperparameters. The results provide critical insights into the operational health of the Tainter valve system, enabling more reliable diagnostics and predictive maintenance for lock machinery, although the approach could be applied to detecting impulsive signals in any time series application.

Authors

Institutions

Publication Details

Journal
Structural Health Monitoring
Published
2025-09-02
DOI
https://doi.org/10.1177/14759217251355209
Citations
1
Primary Topic
Hydraulic and Pneumatic Systems
Type
article
Field-Weighted Citation Impact
0.71

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hierarchical Bayesian detection of impulses in Tainter valve machinery systems under uncertainty

Joey Reed, Brian Eick, Xu Huang, César Ortíz et al.
1 citations
Structural Health Monitoring
Hydraulic and Pneumatic Systems
0.71
article

Hierarchical Bayesian detection of impulses in Tainter valve machinery systems under uncertainty

Joey Reed, Brian Eick, Xu Huang, César Ortíz, Michael D. Todd, D. Sean Barnett, Lin Sun
article en
1 citations

Abstract

Reliable lock operation is crucial for uninterrupted waterway traffic, but failures in fill/empty Tainter valves can hinder lock management. To address this, an in-service lock was instrumented with an array of sensors spanning the motor to the final gear shaft. Unexpected impulses were observed in the jack shaft and sector gear bearing block accelerometer signals during certain valve opening events, coinciding with anomalies in sector gear angular displacement signals. To detect these impulses, a single-channel hierarchical Bayesian framework was employed, utilizing sector gear bearing block acceleration signals. A binary hierarchical Bayesian hypothesis testing approach was developed, assuming Gaussian noise versus Gaussian-distributed signals conditioned on the mean and standard deviation (STD) of the impulses. Unlike traditional Bayesian detection methods that pool all datasets/events together or analyze single events/datasets in isolation, this approach captures aleatory and epistemic uncertainties by modeling the impulse signal mean and dispersion as random variables (RVs). The relationships among different detection models (Neyman–Pearson detection, matched filter, Bayesian detection, and hierarchical Bayesian detection) are mathematically demonstrated, showing how they are interconnected. To address signal non-stationarity within events and signal magnitude across multiple events, optimal windowing and signal normalization were applied to ensure statistical reliability and computational efficiency. A local sensitivity analysis was performed to determine the effect of the decision threshold in this binary hypothesis testing to the hyperparameters. The results provide critical insights into the operational health of the Tainter valve system, enabling more reliable diagnostics and predictive maintenance for lock machinery, although the approach could be applied to detecting impulsive signals in any time series application.

Structural Health Monitoring
University of California San Diego (US), Elintrix (United States) (US), U.S. Army Engineer Research and Development Center (US)
Engineer Research and Development Center
Openalex Percentile: Top 28%
Hydraulic and Pneumatic Systems
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.