Indoor Air Quality Assessment Based on Floor-Level Variations in a University Library

Libraries are environments where students often spend extended periods due to their conducive and quiet atmosphere that supports focused learning. However, poor indoor air quality (IAQ) in such settings can negatively impact cognitive performance and pose health risks. This study aimed to assess the IAQ at Levels 1 and 3 of the Dr. Abdul Latiff Library, Universiti Kebangsaan Malaysia, by evaluating physical, chemical, and biological parameters, as well as ventilation performance indicators. Data were collected through walkthrough inspections, direct measurements, and questionnaires distributed to library staff and users. The results revealed that temperature readings at sampling points 4, 5, and 6 exceeded the ICOP IAQ 2010 acceptable limits, while air movement across all sampling points fell below the recommended range. Other IAQ parameters remained within acceptable limits. Statistically significant differences (p < 0.05) were observed in CO₂ and PM₁₀ levels on Level 1 and in temperature and PM₁₀ levels on Level 3. Although overall IAQ was acceptable, elevated temperatures and inadequate air movement were identified as concerns.

Authors

Institutions

Publication Details

Journal
Oriental Journal Of Chemistry
Published
2025-08-31
DOI
https://doi.org/10.13005/ojc/410431
Primary Topic
Conservation Techniques and Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Indoor Air Quality Assessment Based on Floor-Level Variations in a University Library

Nurul Farahana Kamaludin, Normah Awang, N. Jamaludin, Muhammad Ikram A. Wahab
1 links
Oriental Journal Of Chemistry
Conservation Techniques and Studies
article

Indoor Air Quality Assessment Based on Floor-Level Variations in a University Library

Nurul Farahana Kamaludin, Normah Awang, N. Jamaludin, Muhammad Ikram A. Wahab
article en

Abstract

Libraries are environments where students often spend extended periods due to their conducive and quiet atmosphere that supports focused learning. However, poor indoor air quality (IAQ) in such settings can negatively impact cognitive performance and pose health risks. This study aimed to assess the IAQ at Levels 1 and 3 of the Dr. Abdul Latiff Library, Universiti Kebangsaan Malaysia, by evaluating physical, chemical, and biological parameters, as well as ventilation performance indicators. Data were collected through walkthrough inspections, direct measurements, and questionnaires distributed to library staff and users. The results revealed that temperature readings at sampling points 4, 5, and 6 exceeded the ICOP IAQ 2010 acceptable limits, while air movement across all sampling points fell below the recommended range. Other IAQ parameters remained within acceptable limits. Statistically significant differences (p < 0.05) were observed in CO₂ and PM₁₀ levels on Level 1 and in temperature and PM₁₀ levels on Level 3. Although overall IAQ was acceptable, elevated temperatures and inadequate air movement were identified as concerns.

Oriental Journal Of ChemistryVol. 41(4)
National University of Malaysia (MY)
Openalex Percentile: Top 71%
Conservation Techniques and Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Indoor Air Quality Assessment Based on Floor-Level Variations in a University Library — Nurul Farahana Kamaludin, Normah Awang, et al. · Oriental Journal Of Chemistry (2025) | TGRS Research Map | TGRS