Infrared Sensor Measurement of Neck Carotid Skin Temperature in the Emergency Department: A Safe Alternative to the Tympanic Method

The demand for rapid, non-contact, and reliable body temperature measurement in emergency departments is growing. Although tympanic thermometers are commonly used, limitations, including measurement errors and patient non-compliance, necessitate alternative methods. This study evaluated the clinical reliability of infrared sensors for measuring cervical carotid artery skin temperature, using the Braun ThermoScan 7 tympanic thermometer as a reference. In a prospective cross-sectional study, 520 patients aged 18–65 underwent three measurements in the carotid region using a FLIR T530 infrared sensor. Inter-method agreement was assessed via Bland-Altman analysis, Intraclass Correlation Coefficient (ICC), and Deming regression, with ambient temperature maintained at 20–30±1°C. Results revealed a mean difference of 0.14°C (±0.21°C) between tympanic and carotid infrared measurements, high agreement (ICC=0.93, p<0.001), and a strong linear relationship (R²=0.89). Carotid measurement time was 64% shorter than the tympanic method. Ambient temperature variations had minimal impact on accuracy (1.1% variation). Infrared sensors provide a robust alternative for non-contact, rapid, and reliable temperature measurement in emergency settings, enhancing infection control and triage efficiency.

Authors

Institutions

Publication Details

Journal
Oriental Journal Of Chemistry
Published
2025-08-31
DOI
https://doi.org/10.13005/ojc/410428
Primary Topic
Infrared Thermography in Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Infrared Sensor Measurement of Neck Carotid Skin Temperature in the Emergency Department: A Safe Alternative to the Tympanic Method

Yakup Budak, Serhat Karaman, Esra Tapar
Oriental Journal Of Chemistry
Infrared Thermography in Medicine
article

Infrared Sensor Measurement of Neck Carotid Skin Temperature in the Emergency Department: A Safe Alternative to the Tympanic Method

Yakup Budak, Serhat Karaman, Esra Tapar
article en

Abstract

The demand for rapid, non-contact, and reliable body temperature measurement in emergency departments is growing. Although tympanic thermometers are commonly used, limitations, including measurement errors and patient non-compliance, necessitate alternative methods. This study evaluated the clinical reliability of infrared sensors for measuring cervical carotid artery skin temperature, using the Braun ThermoScan 7 tympanic thermometer as a reference. In a prospective cross-sectional study, 520 patients aged 18–65 underwent three measurements in the carotid region using a FLIR T530 infrared sensor. Inter-method agreement was assessed via Bland-Altman analysis, Intraclass Correlation Coefficient (ICC), and Deming regression, with ambient temperature maintained at 20–30±1°C. Results revealed a mean difference of 0.14°C (±0.21°C) between tympanic and carotid infrared measurements, high agreement (ICC=0.93, p<0.001), and a strong linear relationship (R²=0.89). Carotid measurement time was 64% shorter than the tympanic method. Ambient temperature variations had minimal impact on accuracy (1.1% variation). Infrared sensors provide a robust alternative for non-contact, rapid, and reliable temperature measurement in emergency settings, enhancing infection control and triage efficiency.

Oriental Journal Of ChemistryVol. 41(4)
Tokat Gaziosmanpaşa Üniversitesi (TR)
Openalex Percentile: Top 68%
Infrared Thermography in Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.