Core–Valence-Luminescence Cs–M–Cl (M = Zn, Mg) Scintillators for Photon-Counting X-ray Detectors

X-ray photon-counting detectors (PCDs) are a rapidly developing technology used in medical imaging. Current PCDs are based on room-temperature semiconductors, such as CdTe and CZT, directly converting incident X-ray photons into electrical pulses. An alternative to this approach is the use of ultrafast scintillators in combination with silicon photomultipliers. A very interesting class of materials potentially suitable for this application is scintillators exhibiting core–valence luminescence (CVL), which typically has a decay time between 0.5 and 2 ns. In this work, two families of Cs–Cl-based compounds, Cs–Zn–Cl and Cs–Mg–Cl, are investigated for their potential application in PCDs. These families of compounds are especially interesting because most members exclusively show CVL at room temperature, resulting in a fast scintillation pulse containing no slow components. Additionally, several approaches to tailor the scintillation properties of these materials, i.e., doping with Br– and Zn2+, are studied. Unfortunately, all compounds show a strong drop in the CVL response in the diagnostic energy range (25–150 keV), the operational range of a PCD. PCDs based on these materials will thus be able to handle the high X-ray fluence rate of an imaging task but will not be able to sufficiently discriminate the energies of incident X-ray photons. In addition to the Cs–Zn–Cl and Cs–Mg–Cl compounds, the nonproportional response of the CVL component of BaF2 is studied utilizing fast digitization of individual scintillation pulses in order to discriminate between processes related to the CVL and self-trapped exciton emission of BaF2.

Authors

Institutions

Publication Details

Journal
ACS Applied Optical Materials
Published
2025-09-01
DOI
https://doi.org/10.1021/acsaom.5c00253
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Core–Valence-Luminescence Cs–M–Cl (M = Zn, Mg) Scintillators for Photon-Counting X-ray Detectors

P. Dorenbos, Luis Stand, Dennis R. Schaart, Casper van Aarle et al.
1 citations
ACS Applied Optical Materials
Advanced X-ray and CT Imaging
0.67
article

Core–Valence-Luminescence Cs–M–Cl (M = Zn, Mg) Scintillators for Photon-Counting X-ray Detectors

P. Dorenbos, Luis Stand, Dennis R. Schaart, Casper van Aarle, Charles L. Melcher, J. Jasper van Blaaderen, Mariya Zhuravleva, Daniel Rutstrom, J. de Haas, Giles Bangoyina
article en
1 citations

Abstract

X-ray photon-counting detectors (PCDs) are a rapidly developing technology used in medical imaging. Current PCDs are based on room-temperature semiconductors, such as CdTe and CZT, directly converting incident X-ray photons into electrical pulses. An alternative to this approach is the use of ultrafast scintillators in combination with silicon photomultipliers. A very interesting class of materials potentially suitable for this application is scintillators exhibiting core–valence luminescence (CVL), which typically has a decay time between 0.5 and 2 ns. In this work, two families of Cs–Cl-based compounds, Cs–Zn–Cl and Cs–Mg–Cl, are investigated for their potential application in PCDs. These families of compounds are especially interesting because most members exclusively show CVL at room temperature, resulting in a fast scintillation pulse containing no slow components. Additionally, several approaches to tailor the scintillation properties of these materials, i.e., doping with Br– and Zn2+, are studied. Unfortunately, all compounds show a strong drop in the CVL response in the diagnostic energy range (25–150 keV), the operational range of a PCD. PCDs based on these materials will thus be able to handle the high X-ray fluence rate of an imaging task but will not be able to sufficiently discriminate the energies of incident X-ray photons. In addition to the Cs–Zn–Cl and Cs–Mg–Cl compounds, the nonproportional response of the CVL component of BaF2 is studied utilizing fast digitization of individual scintillation pulses in order to discriminate between processes related to the CVL and self-trapped exciton emission of BaF2.

ACS Applied Optical MaterialsVol. 3(9)
Proton Therapy Centre (CZ), Institute for Scintillation Materials (UA), University of Tennessee at Knoxville (US), Delft University of Technology (NL)
U.S. Department of Energy, Technische Universiteit Delft, Delft Research Centres, National Nuclear Security Administration
Openalex Percentile: Top 27%
Advanced X-ray and CT Imaging
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.