Effects of Different Inertial Measurement Unit Sensor-to-Segment Calibrations on Clinical 3-Dimensional Wrist Joint Angles Estimation

Inertial Measurement Units (IMUs) enable accurate estimation of anatomical joint angles but require a sensor-to-segment calibration. Literature has presented several algorithms that address this gap; however, adequately comparing calibration performance is not trivial. This study compares 3 calibration methods: N-pose calibration (NP), functional calibration (FC), and manual alignment (MA) to estimate 3D wrist joint angles during single-plane and multiplane tasks. Thirteen healthy participants were instrumented with IMUs and optical markers to compute the range of motion error (ε), root mean squared error, and offset between the joint angles from the optical reference and each IMU calibration (NP, FC, and MA) as dependent variables. We then performed 3-way repeated-measures analyses of variance on each dependent variable to evaluate interactions between calibrations, tasks, and joint axes. NP showed the worst root mean squared error (8.34° [7.41°]) performance in the calibration main effect (η2G = .095) and calibration × tasks interaction (η2G = .121). In an exploratory analysis, FC performed best (main effect root mean squared error = 6.52° [4.47°]) in the offset calibration × axes interaction in single-plane (η2G = .160) tasks. Therefore, we recommend FC to optimally perform wrist calibration and against NP. These findings are viable in aiding the development of portable IMU-based clinical motion-tracking devices.

Authors

Institutions

Publication Details

Journal
Journal of Applied Biomechanics
Published
2025-01-01
DOI
https://doi.org/10.1123/jab.2024-0283
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Different Inertial Measurement Unit Sensor-to-Segment Calibrations on Clinical 3-Dimensional Wrist Joint Angles Estimation

Elisabetta Farella, Alessandro Bonfiglio, Raoul M. Bongers
1 links
Journal of Applied Biomechanics
Shoulder Injury and Treatment
article

Effects of Different Inertial Measurement Unit Sensor-to-Segment Calibrations on Clinical 3-Dimensional Wrist Joint Angles Estimation

Elisabetta Farella, Alessandro Bonfiglio, Raoul M. Bongers
article en

Abstract

Inertial Measurement Units (IMUs) enable accurate estimation of anatomical joint angles but require a sensor-to-segment calibration. Literature has presented several algorithms that address this gap; however, adequately comparing calibration performance is not trivial. This study compares 3 calibration methods: N-pose calibration (NP), functional calibration (FC), and manual alignment (MA) to estimate 3D wrist joint angles during single-plane and multiplane tasks. Thirteen healthy participants were instrumented with IMUs and optical markers to compute the range of motion error (ε), root mean squared error, and offset between the joint angles from the optical reference and each IMU calibration (NP, FC, and MA) as dependent variables. We then performed 3-way repeated-measures analyses of variance on each dependent variable to evaluate interactions between calibrations, tasks, and joint axes. NP showed the worst root mean squared error (8.34° [7.41°]) performance in the calibration main effect (η2G = .095) and calibration × tasks interaction (η2G = .121). In an exploratory analysis, FC performed best (main effect root mean squared error = 6.52° [4.47°]) in the offset calibration × axes interaction in single-plane (η2G = .160) tasks. Therefore, we recommend FC to optimally perform wrist calibration and against NP. These findings are viable in aiding the development of portable IMU-based clinical motion-tracking devices.

Journal of Applied BiomechanicsVol. 41(5)
University Medical Center Groningen (NL), University of Trento (IT), Fondazione Bruno Kessler (IT)
Openalex Percentile: Top 63%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effects of Different Inertial Measurement Unit Sensor-to-Segment Calibrations on Clinical 3-Dimensional Wrist Joint Angles Estimation — Elisabetta Farella, Alessandro Bonfiglio, et al. · Journal of Applied Biomechanics (2025) | TGRS Research Map | TGRS