Open-Loop Performance Analysis of Induction Motors under V/f Speed Control

This study aims to analyze the performance of a three-phase induction motor with a speed control system based on the Volt per Hertz (V/f) method in an open-loop configuration, with a primary focus on reducing torque drop during low-frequency operation. The simulation was carried out using MATLAB/Simulink, where the model consists of an SPWM-based three-phase inverter, a standard Simulink induction motor, and an external mechanical load. The V/f method was applied to maintain constant stator flux by keeping the voltage-to-frequency ratio fixed (approximately 7.6 V/Hz). The input frequency was varied from 10 Hz to 50 Hz, both under no-load and loaded conditions. The observed performance parameters included rotor speed, electromagnetic torque, stator current, and motor slip. The simulation results show that the system can produce a linear relationship between frequency and rotor speed with low slip (<5%) under no-load conditions. However, under load conditions, there is a speed drop of around 4–5% that cannot be compensated due to the absence of a feedback system. The initial electromagnetic torque demonstrates a fast response with an overshoot of up to 150 Nm before stabilizing in the range of 100–120 Nm. The rotor speed reaches a steady-state condition in approximately 0.2 seconds, indicating good dynamic response. In conclusion, the open-loop V/f control system is effective and sufficiently efficient for light industrial applications that do not require high precision, such as fans and pumps. However, for applications that demand greater stability and dynamic response, further development toward a closed-loop system or sensor-based adaptive control is recommended to enhance control accuracy, energy efficiency, and system capability in responding to dynamic loads

Authors

Publication Details

Journal
DIELEKTRIKA
Published
2025-09-01
DOI
https://doi.org/10.29303/dielektrika.v12i2.422
Primary Topic
Sensorless Control of Electric Motors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Open-Loop Performance Analysis of Induction Motors under V/f Speed Control

I Nyoman Wahyu Satiawan, I Ketut Wirya Jati
DIELEKTRIKA
Sensorless Control of Electric Motors
article

Open-Loop Performance Analysis of Induction Motors under V/f Speed Control

I Nyoman Wahyu Satiawan, I Ketut Wirya Jati
article en

Abstract

This study aims to analyze the performance of a three-phase induction motor with a speed control system based on the Volt per Hertz (V/f) method in an open-loop configuration, with a primary focus on reducing torque drop during low-frequency operation. The simulation was carried out using MATLAB/Simulink, where the model consists of an SPWM-based three-phase inverter, a standard Simulink induction motor, and an external mechanical load. The V/f method was applied to maintain constant stator flux by keeping the voltage-to-frequency ratio fixed (approximately 7.6 V/Hz). The input frequency was varied from 10 Hz to 50 Hz, both under no-load and loaded conditions. The observed performance parameters included rotor speed, electromagnetic torque, stator current, and motor slip. The simulation results show that the system can produce a linear relationship between frequency and rotor speed with low slip (<5%) under no-load conditions. However, under load conditions, there is a speed drop of around 4–5% that cannot be compensated due to the absence of a feedback system. The initial electromagnetic torque demonstrates a fast response with an overshoot of up to 150 Nm before stabilizing in the range of 100–120 Nm. The rotor speed reaches a steady-state condition in approximately 0.2 seconds, indicating good dynamic response. In conclusion, the open-loop V/f control system is effective and sufficiently efficient for light industrial applications that do not require high precision, such as fans and pumps. However, for applications that demand greater stability and dynamic response, further development toward a closed-loop system or sensor-based adaptive control is recommended to enhance control accuracy, energy efficiency, and system capability in responding to dynamic loads

DIELEKTRIKAVol. 12(2)
Universitas Mataram
Openalex Percentile: Top 78%
Sensorless Control of Electric Motors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.