Stability Indicating Spectrofluorimetric Method for the Estimation of Escitalopram in Bulk and Pharmaceutical Dosage Form

Aim: The purpose of this research was to design and validate a reliable, sensitive, and accurate spectrofluorimetric approach for the determination of Escitalopram. Materials and Methods: Acetonitrile was used as the solvent, and the λmax was determined to be 239 nm. The technique has been applicable for accuracy, limit of detection (LOD), linearity, limit of quantification (LOQ), as well as precision. Results: On the basis of the results, escitalopram had a correlation coefficient of 0.9992 as well as was linear in 1–9µg/mL range. Value of LOD had been 0.112µg/mL, whereas LOQ had been 0.370µg/mL. Stability studies demonstrated that Escitalopram was vulnerable to alkaline, acid, along with oxidative degradation. Conclusion: The developed spectrofluorimetric method has been discovered to be sensitive, simple, and appropriate for Escitalopram quantification. The method met the ICH guidelines for linearity, precision, LOD, accuracy, and LOQ, making it suitable for regular quality inspection of Active Pharmaceutical Ingredient (API) and formulations.

Authors

Institutions

Publication Details

Journal
Oriental Journal Of Chemistry
Published
2025-08-31
DOI
https://doi.org/10.13005/ojc/410419
Primary Topic
Molecular spectroscopy and chirality
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stability Indicating Spectrofluorimetric Method for the Estimation of Escitalopram in Bulk and Pharmaceutical Dosage Form

Barla Karuna Devi, Panikumar Durga Anumolu, Veluvolu Tejaswini
Oriental Journal Of Chemistry
Molecular spectroscopy and chirality
article

Stability Indicating Spectrofluorimetric Method for the Estimation of Escitalopram in Bulk and Pharmaceutical Dosage Form

Barla Karuna Devi, Panikumar Durga Anumolu, Veluvolu Tejaswini
article en

Abstract

Aim: The purpose of this research was to design and validate a reliable, sensitive, and accurate spectrofluorimetric approach for the determination of Escitalopram. Materials and Methods: Acetonitrile was used as the solvent, and the λmax was determined to be 239 nm. The technique has been applicable for accuracy, limit of detection (LOD), linearity, limit of quantification (LOQ), as well as precision. Results: On the basis of the results, escitalopram had a correlation coefficient of 0.9992 as well as was linear in 1–9µg/mL range. Value of LOD had been 0.112µg/mL, whereas LOQ had been 0.370µg/mL. Stability studies demonstrated that Escitalopram was vulnerable to alkaline, acid, along with oxidative degradation. Conclusion: The developed spectrofluorimetric method has been discovered to be sensitive, simple, and appropriate for Escitalopram quantification. The method met the ICH guidelines for linearity, precision, LOD, accuracy, and LOQ, making it suitable for regular quality inspection of Active Pharmaceutical Ingredient (API) and formulations.

Oriental Journal Of ChemistryVol. 41(4)
JK Agri Genetics (India) (IN)
Openalex Percentile: Top 79%
Molecular spectroscopy and chirality
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Stability Indicating Spectrofluorimetric Method for the Estimation of Escitalopram in Bulk and Pharmaceutical Dosage Form — Barla Karuna Devi, Panikumar Durga Anumolu, et al. · Oriental Journal Of Chemistry (2025) | TGRS Research Map | TGRS