Influence of partial discharging in a latent heat thermal energy storage unit: 3D numerical study

A deep understanding of the various operating modes is crucial to ensure an optimum exploitation of latent thermal storage systems. Incomplete discharge constitutes one of these operating modes, which can be of great interest, for example, in fluctuating demand situations. In the present paper, a 3D numerical study is carried out to investigate the effect of partial discharge on the performance of a finned multitube latent heat thermal energy storage unit. The analysis is performed on both the discharge and the subsequent charging processes. Partial discharge with 80% total solidification and full discharge with 100% solidification are compared in terms of process duration and energy released/stored. Erythritol and hytherm 600 were utilized as phase change material and heat transfer fluid, respectively. The results show that during the discharge process, partial discharge saves 47.7% of the process time, with only 20.7% of unused energy. As for the following charge, an equivalent time saving and unused energy of 20.4% and 21.5%, respectively, are obtained after a partial discharge as compared to full discharge. Furthermore, the local analysis shows that the melting front evolution is influenced by the partial discharge.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-09-01
DOI
https://doi.org/10.1049/icp.2025.2671
Primary Topic
Phase Change Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of partial discharging in a latent heat thermal energy storage unit: 3D numerical study

Daniel Bougeard, Adrian Ilinca, Lionel Nadau, J.V. Simo Tala et al.
IET conference proceedings.
Phase Change Materials Research
article

Influence of partial discharging in a latent heat thermal energy storage unit: 3D numerical study

Daniel Bougeard, Adrian Ilinca, Lionel Nadau, J.V. Simo Tala, Soumaya Sokakini
article en

Abstract

A deep understanding of the various operating modes is crucial to ensure an optimum exploitation of latent thermal storage systems. Incomplete discharge constitutes one of these operating modes, which can be of great interest, for example, in fluctuating demand situations. In the present paper, a 3D numerical study is carried out to investigate the effect of partial discharge on the performance of a finned multitube latent heat thermal energy storage unit. The analysis is performed on both the discharge and the subsequent charging processes. Partial discharge with 80% total solidification and full discharge with 100% solidification are compared in terms of process duration and energy released/stored. Erythritol and hytherm 600 were utilized as phase change material and heat transfer fluid, respectively. The results show that during the discharge process, partial discharge saves 47.7% of the process time, with only 20.7% of unused energy. As for the following charge, an equivalent time saving and unused energy of 20.4% and 21.5%, respectively, are obtained after a partial discharge as compared to full discharge. Furthermore, the local analysis shows that the melting front evolution is influenced by the partial discharge.

IET conference proceedings.Vol. 2025(19)
Institut Mines-Télécom (FR), École de Technologie Supérieure (CA)
Openalex Percentile: Top 77%
Phase Change Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.