Finite element modeling of pedicle screw fixation considering patient-specific bone density

Surgical instrumentation and fusion are necessary in severe cases of spinal deformity. In patients with reduced bone quality, pedicle screw fixation remains challenging due to possible loosening or pullout. The objective was to develop and validate a comprehensive finite element model of pedicle screw fixation considering patient-specific bone density. A bi-planar multi-energy X-ray derived algorithm personalized vertebral bone mechanical properties. It was tested against a reference FEM without patient-specific density (trabecular bone modeled as homogeneous), to assess biomechanical performance. Screw dimensional specifications and trajectory were parametrically modeled, and fixation performance was tested under axial pull-out loads.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2025-09-01
DOI
https://doi.org/10.1080/10255842.2025.2552437
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite element modeling of pedicle screw fixation considering patient-specific bone density

Isabelle Villemure, Carl‐Éric Aubin, Carolina Solórzano Barrera, Marie-Hélène Beauséjour et al.
Computer Methods in Biomechanics & Biomedical Engineering
Spinal Fractures and Fixation Techniques
article

Finite element modeling of pedicle screw fixation considering patient-specific bone density

Isabelle Villemure, Carl‐Éric Aubin, Carolina Solórzano Barrera, Marie-Hélène Beauséjour, Ningxin Qiao, Duc Nguyen
article en

Abstract

Surgical instrumentation and fusion are necessary in severe cases of spinal deformity. In patients with reduced bone quality, pedicle screw fixation remains challenging due to possible loosening or pullout. The objective was to develop and validate a comprehensive finite element model of pedicle screw fixation considering patient-specific bone density. A bi-planar multi-energy X-ray derived algorithm personalized vertebral bone mechanical properties. It was tested against a reference FEM without patient-specific density (trabecular bone modeled as homogeneous), to assess biomechanical performance. Screw dimensional specifications and trajectory were parametrically modeled, and fixation performance was tested under axial pull-out loads.

Computer Methods in Biomechanics & Biomedical Engineering
Centre Hospitalier Universitaire Sainte-Justine (CA), Polytechnique Montréal (CA), École de Technologie Supérieure (CA)
Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 63%
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.