Functioning and Safety of the Non-Invasive Corneal Esthesiometer Brill: A Multicenter Study

<b>Background/Objectives</b>: Corneal sensitivity can be decreased by several ocular conditions, including dry eye and refractive surgery, which can lead to ocular epithelial lesions. This decrease can be detected by esthesiometry. The main objective of this study was to evaluate the performance, safety, and efficacy of the Corneal Esthesiometer Brill in healthy subjects without ocular pathologies. <b>Methods</b>: A controlled, randomized, prospective, multicenter pilot clinical study was conducted in adult patients with healthy eyes. Corneal sensitivity measurements were made three times for one eye randomly selected to obtain the corneal sensitivity reference ranges. Additionally, one more measurement was taken after the application of a topical anesthetic. An intra- and inter-observer analysis was performed to assess user dependence, and the last measurement was taken after ocular topical anesthesia to evaluate the device's sensitivity in detecting corneal sensitivity loss. <b>Results</b>: Ninety-one volunteers were included with a mean age of 25 (SD 3.46, range 18-30), and fifty-eight (63.7%) were female. Corneal sensitivity reference levels ranged from level 2 (3-4 mbar) to level 3 (4-5 mbar). Intra- and inter-observer measurement differences on the same subject without anesthesia were not statistically significant. Corneal pressure before and after local ocular anesthesia had statistically significant differences (<i>p</i> < 0.0001). <b>Conclusions</b>: The Corneal Esthesiometer Brill yielded consistent and reproducible measurements in young volunteers with healthy eyes, enabling objective, observer-independent use and facilitating the detection of significant loss of sensitivity.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-08-30
DOI
https://doi.org/10.3390/diagnostics15172208
Citations
2
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
3.76
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Functioning and Safety of the Non-Invasive Corneal Esthesiometer Brill: A Multicenter Study

Concepción Renedo Laguna, Jesús Merayo‐Lloves, J.M. Benítez-del-Castillo, Carmen Gómez Martín et al.
2 citations
Diagnostics
Ocular Surface and Contact Lens
3.76
article

Functioning and Safety of the Non-Invasive Corneal Esthesiometer Brill: A Multicenter Study

Concepción Renedo Laguna, Jesús Merayo‐Lloves, J.M. Benítez-del-Castillo, Carmen Gómez Martín, Salvador García Delpech, J. Bueno Lozano, Jesús Montero Iruzubieta
article en
2 citations

Abstract

<b>Background/Objectives</b>: Corneal sensitivity can be decreased by several ocular conditions, including dry eye and refractive surgery, which can lead to ocular epithelial lesions. This decrease can be detected by esthesiometry. The main objective of this study was to evaluate the performance, safety, and efficacy of the Corneal Esthesiometer Brill in healthy subjects without ocular pathologies. <b>Methods</b>: A controlled, randomized, prospective, multicenter pilot clinical study was conducted in adult patients with healthy eyes. Corneal sensitivity measurements were made three times for one eye randomly selected to obtain the corneal sensitivity reference ranges. Additionally, one more measurement was taken after the application of a topical anesthetic. An intra- and inter-observer analysis was performed to assess user dependence, and the last measurement was taken after ocular topical anesthesia to evaluate the device's sensitivity in detecting corneal sensitivity loss. <b>Results</b>: Ninety-one volunteers were included with a mean age of 25 (SD 3.46, range 18-30), and fifty-eight (63.7%) were female. Corneal sensitivity reference levels ranged from level 2 (3-4 mbar) to level 3 (4-5 mbar). Intra- and inter-observer measurement differences on the same subject without anesthesia were not statistically significant. Corneal pressure before and after local ocular anesthesia had statistically significant differences (<i>p</i> < 0.0001). <b>Conclusions</b>: The Corneal Esthesiometer Brill yielded consistent and reproducible measurements in young volunteers with healthy eyes, enabling objective, observer-independent use and facilitating the detection of significant loss of sensitivity.

DiagnosticsVol. 15(17)
Universidad Complutense de Madrid (ES), Universidad de Oviedo (ES), Clínica Rementería (ES), Institute of Space Sciences (ES), Fernández-Vega Ophthalmological Institute (ES), IVI Valencia Clinic (ES), Centro de Investigaciones Científicas Isla de la Cartuja (ES)
Openalex Percentile: Top 6%
Ocular Surface and Contact Lens
3.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.