Simulation, Fabrication, and Characterization of Bismuth Oxide-Ethylene Vinyl Acetate (Bi2O3-EVA) Composite As a Cesium-137 Gamma Radiation Shield

Prolonged exposure to cesium-137 (Cs-137) gamma radiation, a high-energy source widely used in medicine, is known to cause cellular damage and increased rates of cancer. Wearable lead-lined radiation shields provide a direct protective barrier that attenuates ionizing radiation. Aside from being toxic, lead is heavy and rigid-this limits the dexterity of medical workers. Non-toxic polymer composites are promising solutions as they combine high attenuation rates of high-density materials with the lightness and flexibility of polymers. In this study, a composite consisting of bismuth oxide and ethylene vinyl acetate (Bi2O3-EVA) was simulated, fabricated, and characterized to determine its structural and radiation shielding performance. The simulation results determined that increasing Bi2O3 filler content enhances shielding performance. Bi2O3-EVA composites were then fabricated through melt-mixing methods and compression molding. Radiation shield testing showed that composites with higher Bi2O3 filler content displayed improved shielding efficiencies, with higher linear attenuation coefficients and lower half-value layer thicknesses. Samples consisting of 60% Bi2O3 by weight produced optimal shielding performance, achieving half-value layer values between 1.508 cm and 1.878 cm. Analysis of homogeneity levels through the ISO-based rapid comparative method and texture analysis yielded acceptable values, entailing that its consistent structure does not compromise radiation shielding performance. Moreover, the tensile strength is maintained even at a high 80% Bi2O3 by weight. The positive results obtained in this study present new opportunities for developing lighter and more flexible wearable medical gamma radiation shields that effectively attenuate gamma radiation.

Authors

Publication Details

Journal
Cureus Journal of Engineering.
Published
2025-09-01
DOI
https://doi.org/10.7759/s44388-025-05226-z
Primary Topic
Radiation Shielding Materials Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation, Fabrication, and Characterization of Bismuth Oxide-Ethylene Vinyl Acetate (Bi2O3-EVA) Composite As a Cesium-137 Gamma Radiation Shield

Ricardo Fernández, Juan Carlos Valladares de la Cruz, Kyle Noah D Esguerra, John Dominic L Sapao
Cureus Journal of Engineering.
Radiation Shielding Materials Analysis
article

Simulation, Fabrication, and Characterization of Bismuth Oxide-Ethylene Vinyl Acetate (Bi2O3-EVA) Composite As a Cesium-137 Gamma Radiation Shield

Ricardo Fernández, Juan Carlos Valladares de la Cruz, Kyle Noah D Esguerra, John Dominic L Sapao
article en

Abstract

Prolonged exposure to cesium-137 (Cs-137) gamma radiation, a high-energy source widely used in medicine, is known to cause cellular damage and increased rates of cancer. Wearable lead-lined radiation shields provide a direct protective barrier that attenuates ionizing radiation. Aside from being toxic, lead is heavy and rigid-this limits the dexterity of medical workers. Non-toxic polymer composites are promising solutions as they combine high attenuation rates of high-density materials with the lightness and flexibility of polymers. In this study, a composite consisting of bismuth oxide and ethylene vinyl acetate (Bi2O3-EVA) was simulated, fabricated, and characterized to determine its structural and radiation shielding performance. The simulation results determined that increasing Bi2O3 filler content enhances shielding performance. Bi2O3-EVA composites were then fabricated through melt-mixing methods and compression molding. Radiation shield testing showed that composites with higher Bi2O3 filler content displayed improved shielding efficiencies, with higher linear attenuation coefficients and lower half-value layer thicknesses. Samples consisting of 60% Bi2O3 by weight produced optimal shielding performance, achieving half-value layer values between 1.508 cm and 1.878 cm. Analysis of homogeneity levels through the ISO-based rapid comparative method and texture analysis yielded acceptable values, entailing that its consistent structure does not compromise radiation shielding performance. Moreover, the tensile strength is maintained even at a high 80% Bi2O3 by weight. The positive results obtained in this study present new opportunities for developing lighter and more flexible wearable medical gamma radiation shields that effectively attenuate gamma radiation.

Cureus Journal of Engineering.
Industrial Technology Development Institute, Philippine Nuclear Research Institute
Openalex Percentile: Top 83%
Radiation Shielding Materials Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.