Explosion of a cooling tower dosing system

Abstract An explosion occurred involving a chemical dosing system for cooling tower water at a United States industrial manufacturing facility. Fragments of the dosing system equipment were ejected, causing fatal injuries to the water treatment operator. This was an unusual and unexpected incident for a water treatment system. The system had no automation, data recording, or other means of recording the operator's actions or the process parameters leading up to the incident. This paper will discuss the scientific investigation that gathered the physical and chemical facts and determined the direct causes of the explosion. The dosing system was designed to, among other treatments, provide a biocide at low levels into the cooling water system to control microbiological growth and fouling. The facility had changed biocide chemicals several years prior to this, and leftover drums of a prior biocide had recently been found. The treatment operator made a decision to pump the old biocide into the chemical dosing loop. The investigation determined the sequence of decisions and actions leading up to the explosion. The root causes included a lack of management of change, hazard analysis, and chemical compatibility assessment. This paper will summarize the analysis of these aspects and provide lessons learned.

Authors

Institutions

Publication Details

Journal
Process Safety Progress
Published
2025-09-01
DOI
https://doi.org/10.1002/prs.70017
Primary Topic
Combustion and Detonation Processes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Explosion of a cooling tower dosing system

Brenton L. Cox, Isaac Mastalski, Delmar “Trey” Morrison
1 links
Process Safety Progress
Combustion and Detonation Processes
article

Explosion of a cooling tower dosing system

Brenton L. Cox, Isaac Mastalski, Delmar “Trey” Morrison
article en

Abstract

Abstract An explosion occurred involving a chemical dosing system for cooling tower water at a United States industrial manufacturing facility. Fragments of the dosing system equipment were ejected, causing fatal injuries to the water treatment operator. This was an unusual and unexpected incident for a water treatment system. The system had no automation, data recording, or other means of recording the operator's actions or the process parameters leading up to the incident. This paper will discuss the scientific investigation that gathered the physical and chemical facts and determined the direct causes of the explosion. The dosing system was designed to, among other treatments, provide a biocide at low levels into the cooling water system to control microbiological growth and fouling. The facility had changed biocide chemicals several years prior to this, and leftover drums of a prior biocide had recently been found. The treatment operator made a decision to pump the old biocide into the chemical dosing loop. The investigation determined the sequence of decisions and actions leading up to the explosion. The root causes included a lack of management of change, hazard analysis, and chemical compatibility assessment. This paper will summarize the analysis of these aspects and provide lessons learned.

Process Safety ProgressVol. 45(1)
Exponent (United States) (US)
Openalex Percentile: Top 69%
Combustion and Detonation Processes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Explosion of a cooling tower dosing system — Brenton L. Cox, Isaac Mastalski, et al. · Process Safety Progress (2025) | TGRS Research Map | TGRS