Experimental study on the structural behavior of double z-shaped steel–encased concrete composite beams

This paper presents an experimental investigation into the structural behavior of a novel deck configuration utilizing double Z-shaped steel–concrete composite beams (2ZSCCBs). It is proposed as an alternative to conventional U-shaped steel–concrete composite beams (USCCBs). The 2ZSCCB consists of a plain concrete beam partially encased by double cold-formed Z-shaped steel sections, connected using threaded bolts without welding—addressing the challenges of welding thin-walled sections. The experimental program involved five full-scale beam specimens tested under a four-point bending setup. One specimen was a conventional reinforced concrete beam (BRC), used as the reference, whereas the other four were 2ZSCCBs without traditional shear or flexural reinforcement. Four key parameters were investigated: (i) diameter of bottom flange bolts, (ii) length of bottom flange bolts, (iii) presence of side bolts in the web, and (iv) use of angle connectors. Results showed significant improvements in load-carrying capacity and stiffness for the 2ZSCCB specimens compared to the reference beam. Bolt connectors in the tension zone were especially effective. The ultimate load capacity of the 2ZSCCBs was approximately three times higher than that of the BRC beam with the same cross-section. The use of 12 mm diameter, 80 mm long bolts (B2) at the bottom flange notably enhanced ultimate strength, increased strain energy absorption, developed a tiny relative slip between the bottom flange of 2Z-shaped steel and encased concrete, and changed the failure mode from flexural to shear-compression failure. Additionally, the inclusion of side bolts (B3) further enhanced performance by preventing bolt shear failure and improving energy absorption.

Authors

Institutions

Publication Details

Journal
Alexandria Engineering Journal
Published
2025-09-01
DOI
https://doi.org/10.1016/j.aej.2025.08.034
Citations
1
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.95
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study on the structural behavior of double z-shaped steel–encased concrete composite beams

S.M. Swelem, A. S. Elgamasy, Mohamad S. Shoukry, Ahmed S. Fahmy
1 citations
Alexandria Engineering Journal
Structural Load-Bearing Analysis
0.95
article

Experimental study on the structural behavior of double z-shaped steel–encased concrete composite beams

S.M. Swelem, A. S. Elgamasy, Mohamad S. Shoukry, Ahmed S. Fahmy
article en
1 citations

Abstract

This paper presents an experimental investigation into the structural behavior of a novel deck configuration utilizing double Z-shaped steel–concrete composite beams (2ZSCCBs). It is proposed as an alternative to conventional U-shaped steel–concrete composite beams (USCCBs). The 2ZSCCB consists of a plain concrete beam partially encased by double cold-formed Z-shaped steel sections, connected using threaded bolts without welding—addressing the challenges of welding thin-walled sections. The experimental program involved five full-scale beam specimens tested under a four-point bending setup. One specimen was a conventional reinforced concrete beam (BRC), used as the reference, whereas the other four were 2ZSCCBs without traditional shear or flexural reinforcement. Four key parameters were investigated: (i) diameter of bottom flange bolts, (ii) length of bottom flange bolts, (iii) presence of side bolts in the web, and (iv) use of angle connectors. Results showed significant improvements in load-carrying capacity and stiffness for the 2ZSCCB specimens compared to the reference beam. Bolt connectors in the tension zone were especially effective. The ultimate load capacity of the 2ZSCCBs was approximately three times higher than that of the BRC beam with the same cross-section. The use of 12 mm diameter, 80 mm long bolts (B2) at the bottom flange notably enhanced ultimate strength, increased strain energy absorption, developed a tiny relative slip between the bottom flange of 2Z-shaped steel and encased concrete, and changed the failure mode from flexural to shear-compression failure. Additionally, the inclusion of side bolts (B3) further enhanced performance by preventing bolt shear failure and improving energy absorption.

Alexandria Engineering JournalVol. 128
Alexandria University (EG)
Openalex Percentile: Top 22%
Structural Load-Bearing Analysis
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.