0.08 ppm Scale Factor Nonlinearity in Whole-Angle Hemispherical Resonator Gyroscopes Enabled by Rapid Detection Signal Nonlinearity Suppression

Detection signal nonlinearity, induced by nonlinear capacitive variations in electrode gaps, fundamentally limits the performance of whole-angle (WA) mode hemispherical resonator gyroscopes (HRGs). This letter proposes a rapid identification method for this nonlinearity based on the relationship between the amplitude-gap ratio and resonator vibration energy. Experimental results across 100-500 °/s input rotation velocities confirms method accuracy and operational robustness. Post-compensation HRG achieves a bias instability (BI) of 0.006 °/h and a scale factor nonlinearity (SFN) of 0.08 ppm. The achieved SFN of 0.08 ppm represents the lowest reported value for WA mode HRGs to date.

Authors

Institutions

Publication Details

Journal
IEEE Electron Device Letters
Published
2025-09-01
DOI
https://doi.org/10.1109/led.2025.3604433
Citations
4
Primary Topic
Acoustic Wave Resonator Technologies
Type
article
Field-Weighted Citation Impact
2.70

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

0.08 ppm Scale Factor Nonlinearity in Whole-Angle Hemispherical Resonator Gyroscopes Enabled by Rapid Detection Signal Nonlinearity Suppression

Lituo Shang, Pan Xiao, Jingyu Li, Yao Pan et al.
4 citations
IEEE Electron Device Letters
Acoustic Wave Resonator Technologies
2.70
article

0.08 ppm Scale Factor Nonlinearity in Whole-Angle Hemispherical Resonator Gyroscopes Enabled by Rapid Detection Signal Nonlinearity Suppression

Lituo Shang, Pan Xiao, Jingyu Li, Yao Pan, Hui Luo, Wei Wu, Xingyuan Tang, Libin Zeng
article en
4 citations

Abstract

Detection signal nonlinearity, induced by nonlinear capacitive variations in electrode gaps, fundamentally limits the performance of whole-angle (WA) mode hemispherical resonator gyroscopes (HRGs). This letter proposes a rapid identification method for this nonlinearity based on the relationship between the amplitude-gap ratio and resonator vibration energy. Experimental results across 100-500 °/s input rotation velocities confirms method accuracy and operational robustness. Post-compensation HRG achieves a bias instability (BI) of 0.006 °/h and a scale factor nonlinearity (SFN) of 0.08 ppm. The achieved SFN of 0.08 ppm represents the lowest reported value for WA mode HRGs to date.

IEEE Electron Device LettersVol. 46(11)
Harbin Engineering University (CN), National University of Defense Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 10%
Acoustic Wave Resonator Technologies
2.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.