Performance Evaluation of Magnetocardiography Sensor Arrays via Cramér–Rao Bound for Cardiac Source Localization

Magnetocardiography (MCG) source localisation plays a key role in estimating cardiac electrical activity and identifying abnormal activity locations for disease diagnosis. To improve estimation accuracy in clinical applications, evaluating the performance of MCG sensor arrays is crucial for selecting optimal configurations. Such evaluations have traditionally been conducted through various metrics. However, these metrics depend on specific estimation algorithms and fail to directly reflect how the sensor array influences the variance of parameter estimation. Furthermore, the diversity of estimation algorithms hinders the establishment of uniform assessment criteria. To overcome these challenges, we present an evaluation method for MCG arrays focused on minimising the variance in source parameter estimation. The method leverages the Cramér-Rao Bound (CRB), a theoretical limit on the variance of unbiased estimators and independent of the employed algorithm. Aided by the boundary element method, we derive the CRB framework for estimating cardiac source parameters using MCG data and quantify the effect of adding sensors on the CRB. In addition, we utilise the CRB to evaluate the performance of MCG arrays measuring different magnetic field components, quantifying the advantages of three-dimensional (3D) vector field measurements for source estimation. Compared to conventional radial measurements, 3D vector measurements reduce the equivalent uncertainty radius by more than 25.62%. Finally, we apply the approach to optimise sensor arrangements when the number of sensors is limited. Overall, our results show that the CRB effectively evaluates MCG arrays across diverse configurations, making it applicable to various clinical and engineering applications.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3604125
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Evaluation of Magnetocardiography Sensor Arrays via Cramér–Rao Bound for Cardiac Source Localization

Yadan Zhang, Min Xiang, Peilun Li, Min Zhang et al.
IEEE Transactions on Instrumentation and Measurement
ECG Monitoring and Analysis
article

Performance Evaluation of Magnetocardiography Sensor Arrays via Cramér–Rao Bound for Cardiac Source Localization

Yadan Zhang, Min Xiang, Peilun Li, Min Zhang, Yanmei Wang
article en

Abstract

Magnetocardiography (MCG) source localisation plays a key role in estimating cardiac electrical activity and identifying abnormal activity locations for disease diagnosis. To improve estimation accuracy in clinical applications, evaluating the performance of MCG sensor arrays is crucial for selecting optimal configurations. Such evaluations have traditionally been conducted through various metrics. However, these metrics depend on specific estimation algorithms and fail to directly reflect how the sensor array influences the variance of parameter estimation. Furthermore, the diversity of estimation algorithms hinders the establishment of uniform assessment criteria. To overcome these challenges, we present an evaluation method for MCG arrays focused on minimising the variance in source parameter estimation. The method leverages the Cramér-Rao Bound (CRB), a theoretical limit on the variance of unbiased estimators and independent of the employed algorithm. Aided by the boundary element method, we derive the CRB framework for estimating cardiac source parameters using MCG data and quantify the effect of adding sensors on the CRB. In addition, we utilise the CRB to evaluate the performance of MCG arrays measuring different magnetic field components, quantifying the advantages of three-dimensional (3D) vector field measurements for source estimation. Compared to conventional radial measurements, 3D vector measurements reduce the equivalent uncertainty radius by more than 25.62%. Finally, we apply the approach to optimise sensor arrangements when the number of sensors is limited. Overall, our results show that the CRB effectively evaluates MCG arrays across diverse configurations, making it applicable to various clinical and engineering applications.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Extreme Light Infrastructure - Nuclear Physics (RO), Beihang University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 64%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.