Comparative Study on the Generalization Ability of Machine Learning and Deep Learning Algorithms for Quality Assessment of Wearable PPG Recordings

One of the major challenges in using photoplethysmography (PPG) sensors for heart rate monitoring in real-world settings is ensuring signal quality. This work evaluates and compares machine learning (ML) and deep learning (DL) methods for PPG quality assessment on a unique and comprehensive framework that includes different sensors, wavelengths, body measurement locations, and recording environments. The PPG signals from one proprietary and five publicly available datasets were labeled in terms of quality by comparing the PPG-derived heart rate to a reference heart rate estimated from simultaneous electrocardiograms. Diverse techniques based on common ML classifiers and one- and two-dimensional convolutional neural networks (CNN) were trained on a dataset and tested on the remaining ones. The results showed that several generated models performed comparably to previous studies when they were tested on datasets with similar measurement positions and sensors to the training database. Specifically, reductions in sensitivity, specificity, and F<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub>-score of less than 3% from training to testing were observed on some methods. Contrarily, they reported a notably poorer performance when tested on datasets presenting conditions different from the training. Even the best-performing model, based on the well-known, pre-trained CNN AlexNet, experienced a performance drop of over 20% in that situation. These findings show that the analyzed ML and DL methods lack the ability to generalize across PPG signals captured from diverse environments, sensors, wavelengths, and measurement locations.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3604652
Primary Topic
E-commerce and Technology Innovations
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Study on the Generalization Ability of Machine Learning and Deep Learning Algorithms for Quality Assessment of Wearable PPG Recordings

Roberto Zangróniz, J.J. Rieta, Óscar Ayo‐Martín, Raúl Alcaraz et al.
1 links
IEEE Access
E-commerce and Technology Innovations
article

Comparative Study on the Generalization Ability of Machine Learning and Deep Learning Algorithms for Quality Assessment of Wearable PPG Recordings

Roberto Zangróniz, J.J. Rieta, Óscar Ayo‐Martín, Raúl Alcaraz, Santiago Mula
article en

Abstract

One of the major challenges in using photoplethysmography (PPG) sensors for heart rate monitoring in real-world settings is ensuring signal quality. This work evaluates and compares machine learning (ML) and deep learning (DL) methods for PPG quality assessment on a unique and comprehensive framework that includes different sensors, wavelengths, body measurement locations, and recording environments. The PPG signals from one proprietary and five publicly available datasets were labeled in terms of quality by comparing the PPG-derived heart rate to a reference heart rate estimated from simultaneous electrocardiograms. Diverse techniques based on common ML classifiers and one- and two-dimensional convolutional neural networks (CNN) were trained on a dataset and tested on the remaining ones. The results showed that several generated models performed comparably to previous studies when they were tested on datasets with similar measurement positions and sensors to the training database. Specifically, reductions in sensitivity, specificity, and F<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub>-score of less than 3% from training to testing were observed on some methods. Contrarily, they reported a notably poorer performance when tested on datasets presenting conditions different from the training. Even the best-performing model, based on the well-known, pre-trained CNN AlexNet, experienced a performance drop of over 20% in that situation. These findings show that the analyzed ML and DL methods lack the ability to generalize across PPG signals captured from diverse environments, sensors, wavelengths, and measurement locations.

IEEE AccessVol. 13
Hospital General Universitario de Albacete (ES), Universitat Politècnica de València (ES), University of Castilla-La Mancha (ES)
Generalitat Valenciana, Junta de Comunidades de Castilla-La Mancha, European Regional Development Fund
Openalex Percentile: Top 56%
E-commerce and Technology Innovations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.