Command Approach of a Typical Double-Stage Grid-Connected PV System Under NOM and SGVD

The paper presents a command approach of a typical double-stage grid-connected PV system functioning under Normal Operation Mode (NOM) and Symmetrical Grid Voltage Dips (SGVD). The aim of this proposed command is to contribute to the system stability and ensure connection as long as possible during grid faults. In NOM, the control approach implemented around the double-stage permits to extract the maximum photovoltaic power and regulates, respectively, the dc-link voltage and the inverter output current. Under SGVD, the command approach developed permits to adjust the delivered PV power with the inverter output power at the Point of Common Coupling (PCC). It changes the command signal from its Maximum Power Point (MPP) voltage to a new voltage corresponding to a less power. According to the state of the grid voltage at the PCC and the inverter rating current, the control unit generates instantaneously powers that the inverter can inject to the alternative side. Those powers will be used as references to control the inverter output current, the dc-link voltage control and the operating mode of the MPPT. A case study of a 3 kW solar generator simulated in Matlab/Simulink software is used to illustrate the proposed control.

Authors

Institutions

Publication Details

Published
2025-06-23
DOI
https://doi.org/10.1109/ic_etc65981.2025.11141141
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Command Approach of a Typical Double-Stage Grid-Connected PV System Under NOM and SGVD

Khaireddine Salhi, Rym Marouani, Nejib Hamrouni, Marwen Zaafouri
Photovoltaic System Optimization Techniques
article

Command Approach of a Typical Double-Stage Grid-Connected PV System Under NOM and SGVD

Khaireddine Salhi, Rym Marouani, Nejib Hamrouni, Marwen Zaafouri
article en

Abstract

The paper presents a command approach of a typical double-stage grid-connected PV system functioning under Normal Operation Mode (NOM) and Symmetrical Grid Voltage Dips (SGVD). The aim of this proposed command is to contribute to the system stability and ensure connection as long as possible during grid faults. In NOM, the control approach implemented around the double-stage permits to extract the maximum photovoltaic power and regulates, respectively, the dc-link voltage and the inverter output current. Under SGVD, the command approach developed permits to adjust the delivered PV power with the inverter output power at the Point of Common Coupling (PCC). It changes the command signal from its Maximum Power Point (MPP) voltage to a new voltage corresponding to a less power. According to the state of the grid voltage at the PCC and the inverter rating current, the control unit generates instantaneously powers that the inverter can inject to the alternative side. Those powers will be used as references to control the inverter output current, the dc-link voltage control and the operating mode of the MPPT. A case study of a 3 kW solar generator simulated in Matlab/Simulink software is used to illustrate the proposed control.

Tunis University (TN), University of Carthage (TN), Tunis El Manar University (TN)
Openalex Percentile: Top 85%
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Command Approach of a Typical Double-Stage Grid-Connected PV System Under NOM and SGVD — Khaireddine Salhi, Rym Marouani, et al. · (2025) | TGRS Research Map | TGRS