Measurement Error Analysis and Thermal Degradation Kinetic Model Improvement for Thermogravimetric Analyzers

Thermogravimetric analysis (TGA) has been extensively applied in polymeric characterization and quality inspection, facilitating in-depth investigations of the microstructural thermal response characteristics of polymers, including thermal stability, composition analysis, and thermal decomposition mechanisms. Here, the impacts of six factors on the TG thermal analysis curves obtained during operation are systematically examined while analyzing their causes and recommending solutions. Furthermore, the thermal degradation kinetics of an ionomer formed by neutralizing an ethylene-methacrylic acid copolymer with metal ions (SGP membrane) used in laminated tempered glass is analyzed using the Arrhenius equation, Ozawa-Flynn-Wall hypothesis and Kissinger method. Kinetic parameters at 5% degradation are fitted and used to predict the service lifetime of the SGP membrane. The results indicate that the SGP membrane sample exhibits activation energy <i>Ea</i> = 136.90 kJ/mol, reaction order <i>n</i> = 1.65 and pre-factor <i>A</i> = e<sup>25.93</sup>. It can be seen that the service lifetime of the SGP membrane sample is 16 years at 80 °C and 1.65 years at 100 °C.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2025-09-01
DOI
https://doi.org/10.3390/polym17172390
Citations
1
Primary Topic
Thermal and Kinetic Analysis
Type
article
Field-Weighted Citation Impact
0.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement Error Analysis and Thermal Degradation Kinetic Model Improvement for Thermogravimetric Analyzers

Xiaochun Lu, Zhu-Sen Zhang, Sen Lin, Yaqi Lu et al.
1 citations
Polymers
Thermal and Kinetic Analysis
0.52
article

Measurement Error Analysis and Thermal Degradation Kinetic Model Improvement for Thermogravimetric Analyzers

Xiaochun Lu, Zhu-Sen Zhang, Sen Lin, Yaqi Lu, Guixiang Xie
article en
1 citations

Abstract

Thermogravimetric analysis (TGA) has been extensively applied in polymeric characterization and quality inspection, facilitating in-depth investigations of the microstructural thermal response characteristics of polymers, including thermal stability, composition analysis, and thermal decomposition mechanisms. Here, the impacts of six factors on the TG thermal analysis curves obtained during operation are systematically examined while analyzing their causes and recommending solutions. Furthermore, the thermal degradation kinetics of an ionomer formed by neutralizing an ethylene-methacrylic acid copolymer with metal ions (SGP membrane) used in laminated tempered glass is analyzed using the Arrhenius equation, Ozawa-Flynn-Wall hypothesis and Kissinger method. Kinetic parameters at 5% degradation are fitted and used to predict the service lifetime of the SGP membrane. The results indicate that the SGP membrane sample exhibits activation energy <i>Ea</i> = 136.90 kJ/mol, reaction order <i>n</i> = 1.65 and pre-factor <i>A</i> = e<sup>25.93</sup>. It can be seen that the service lifetime of the SGP membrane sample is 16 years at 80 °C and 1.65 years at 100 °C.

PolymersVol. 17(17)
Huaqiao University (CN), Longyan University (CN)
Natural Science Foundation of Fujian Province, Longyan University
Openalex Percentile: Top 34%
Thermal and Kinetic Analysis
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.