Impact of Ceramic Composition and Thickness on Light Transmission in CAD/CAM Lithium Disilicate Materials: An In Vitro Study

This study investigates light transmission through five types of computer-aided design/computer-aided manufacturing (CAD/CAM) lithium disilicate ceramics, varying in thickness (0.50, 1.00, and 1.50 mm). A total of 150 specimens (10 per group) were fabricated using both traditional and novel ceramic materials: E.max CAD (traditional), n!ce Straumann and LiSi Block GC (fully-crystallized), and Amber Mill and Cerec Tessera (precrystallized). After polishing, light transmission was measured using a curing radiometer and surface microstructures were examined with scanning electron microscopy (SEM). The data were analyzed using two-way analysis of variance (ANOVA) with Tukey's post hoc tests. Results revealed that light intensity decreased as the ceramic thickness increased, regardless of the material type. Amber Mill (0.50 mm) exhibited the highest light intensity at 537 mW/cm<sup>2</sup>, followed by E.max CAD (475 mW/cm<sup>2</sup>) and n!ce Straumann (470 mW/cm<sup>2</sup>). In contrast, LiSi Block GC (1.50 mm) showed no light transmission (0 mW/cm<sup>2</sup>), with Cerec Tessera (60 mW/cm<sup>2</sup>) and E.max CAD (175 mW/cm<sup>2</sup>) also exhibiting low transmission at 1.50 mm. SEM analysis identified structural differences among the materials. These findings suggest that both the composition and thickness of CAD/CAM lithium disilicate ceramics significantly impact light transmission. Results revealed that material composition and thickness significantly influenced light transmission values, underscoring the importance of selecting appropriate ceramic type and thickness to optimize polymerization during light-cured resin cementation in clinical practice.

Authors

Institutions

Publication Details

Journal
International Journal of Dentistry
Published
2025-01-01
DOI
https://doi.org/10.1155/ijod/7488948
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Ceramic Composition and Thickness on Light Transmission in CAD/CAM Lithium Disilicate Materials: An In Vitro Study

Carlos Alberto Jurado, Abdulaziz Alhotan, Salahaldeen Abuhammoud, Austin Green et al.
International Journal of Dentistry
Dental materials and restorations
article

Impact of Ceramic Composition and Thickness on Light Transmission in CAD/CAM Lithium Disilicate Materials: An In Vitro Study

Carlos Alberto Jurado, Abdulaziz Alhotan, Salahaldeen Abuhammoud, Austin Green, Silvia Rojas‐Rueda, Franciele Floriani, Kelvin I. Afrashtehfar
article en

Abstract

This study investigates light transmission through five types of computer-aided design/computer-aided manufacturing (CAD/CAM) lithium disilicate ceramics, varying in thickness (0.50, 1.00, and 1.50 mm). A total of 150 specimens (10 per group) were fabricated using both traditional and novel ceramic materials: E.max CAD (traditional), n!ce Straumann and LiSi Block GC (fully-crystallized), and Amber Mill and Cerec Tessera (precrystallized). After polishing, light transmission was measured using a curing radiometer and surface microstructures were examined with scanning electron microscopy (SEM). The data were analyzed using two-way analysis of variance (ANOVA) with Tukey's post hoc tests. Results revealed that light intensity decreased as the ceramic thickness increased, regardless of the material type. Amber Mill (0.50 mm) exhibited the highest light intensity at 537 mW/cm<sup>2</sup>, followed by E.max CAD (475 mW/cm<sup>2</sup>) and n!ce Straumann (470 mW/cm<sup>2</sup>). In contrast, LiSi Block GC (1.50 mm) showed no light transmission (0 mW/cm<sup>2</sup>), with Cerec Tessera (60 mW/cm<sup>2</sup>) and E.max CAD (175 mW/cm<sup>2</sup>) also exhibiting low transmission at 1.50 mm. SEM analysis identified structural differences among the materials. These findings suggest that both the composition and thickness of CAD/CAM lithium disilicate ceramics significantly impact light transmission. Results revealed that material composition and thickness significantly influenced light transmission values, underscoring the importance of selecting appropriate ceramic type and thickness to optimize polymerization during light-cured resin cementation in clinical practice.

International Journal of DentistryVol. 2025(1)
University of Bern (CH), University of Iowa (US), University of Tennessee Health Science Center (US), Ponce Health Sciences University (PR), King Saud University (SA), University of Iowa Hospitals and Clinics (US), University of Alabama at Birmingham (US), American Academy of Implant Dentistry (US), Alhosn University (AE)
Openalex Percentile: Top 76%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.