High-efficiency chemiluminescent POCT assay for anti-Müllerian hormone: innovative development and application in polycystic ovary syndrome diagnosis

In recent years, the decline in ovarian reserve function has become a major cause of reduced female fertility. Early identification, evaluation, and management of ovarian reserve dysfunction are essential for improving female fertility and reproductive health. Currently, the main diagnostic method is assessing ovarian function through measuring AMH serum concentration and follicle count. Traditional ELISA methods for AMH detection are limited by low sensitivity, long detection times, and susceptibility to manual operation errors. Additionally, many existing AMH measurement techniques require expensive equipment and involve complex procedures, making them less suitable for rapid and accessible clinical use. This study developed a chemiluminescence immunoassay (CLIA) method based on a double-antibody sandwich format for POCT of human serum AMH. A fully automated chemiluminescence immunoassay analyzer is developed independently by our laboratory, without the need for an excitation light source, so that it can be measured on the spot. After incubating the sample with the detection antibody, horseradish peroxidase emits light under substrate catalysis. AMH concentration is detected with a fully automated CLIA instrument, offering high sensitivity, micro-volume, efficiency, and low-cost quantitative POCT detection. Under optimal conditions, the detection limit is 0.02 ng mL<sup>-1</sup>, with a linear range of 0.02-25 ng mL<sup>-1</sup> and a detection time of 35 minutes. The method demonstrates excellent stability, reproducibility, and selectivity. Evaluation of 134 clinical serum samples showed a correlation coefficient (<i>R</i><sup>2</sup>) of 0.9844 with a Beckman CLIA kit. For diagnosing PCOS, the combined detection of DHEAS, LH, and TESTO resulted in an AUC of 0.99. This POCT method offers a fast, reliable tool for assessing AMH levels and improving ovarian reserve evaluation.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay00658a
Citations
2
Primary Topic
Ovarian function and disorders
Type
article
Field-Weighted Citation Impact
3.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-efficiency chemiluminescent POCT assay for anti-Müllerian hormone: innovative development and application in polycystic ovary syndrome diagnosis

Chaolin Guo, Zhonghu Bai, Yinbiao Xu, Yang Sun et al.
2 citations
Analytical Methods
Ovarian function and disorders
3.40
article

High-efficiency chemiluminescent POCT assay for anti-Müllerian hormone: innovative development and application in polycystic ovary syndrome diagnosis

Chaolin Guo, Zhonghu Bai, Yinbiao Xu, Yang Sun, Xiaotong Liu, Meng Liu, Yunyun Zhang, Yu-Peng Liu, Pei Zhou, Hua Li
article en
2 citations

Abstract

In recent years, the decline in ovarian reserve function has become a major cause of reduced female fertility. Early identification, evaluation, and management of ovarian reserve dysfunction are essential for improving female fertility and reproductive health. Currently, the main diagnostic method is assessing ovarian function through measuring AMH serum concentration and follicle count. Traditional ELISA methods for AMH detection are limited by low sensitivity, long detection times, and susceptibility to manual operation errors. Additionally, many existing AMH measurement techniques require expensive equipment and involve complex procedures, making them less suitable for rapid and accessible clinical use. This study developed a chemiluminescence immunoassay (CLIA) method based on a double-antibody sandwich format for POCT of human serum AMH. A fully automated chemiluminescence immunoassay analyzer is developed independently by our laboratory, without the need for an excitation light source, so that it can be measured on the spot. After incubating the sample with the detection antibody, horseradish peroxidase emits light under substrate catalysis. AMH concentration is detected with a fully automated CLIA instrument, offering high sensitivity, micro-volume, efficiency, and low-cost quantitative POCT detection. Under optimal conditions, the detection limit is 0.02 ng mL<sup>-1</sup>, with a linear range of 0.02-25 ng mL<sup>-1</sup> and a detection time of 35 minutes. The method demonstrates excellent stability, reproducibility, and selectivity. Evaluation of 134 clinical serum samples showed a correlation coefficient (<i>R</i><sup>2</sup>) of 0.9844 with a Beckman CLIA kit. For diagnosing PCOS, the combined detection of DHEAS, LH, and TESTO resulted in an AUC of 0.99. This POCT method offers a fast, reliable tool for assessing AMH levels and improving ovarian reserve evaluation.

Analytical MethodsVol. 17(36)
Jiangnan University (CN), Henan University (CN), State Key Laboratory of Synthetic Chemistry (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 7%
Ovarian function and disorders
3.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.