SLIDING MODE CONTROLLED CLOSED LOOP QB-CONVERTER -TPIS FED PMSM DRIVE WITH ENHANCED RESPONSE

The primary goal of this work is to identify the most appropriate controller for a QBC-TPIS fed PMSMD used high performance drives. A drive requires fast dynamic response and accurate control for its operation. This effort deals with the design, analysis &simulation of Closed loop- Quadratic Boost (QB) Converter-TPIS (Three Phase Inverter System) fed PMSM (Permanent Magnet Synchronous Motors) with Proportional-Integral (PI) & SM (Sliding mode) controller outcomes are presented. In this work duty cycle optimization of Q-Boost Converter was done by control input of SM controller. The-consequences are related in terms of-time-domain aspects like –rise-time,-peak-time,-settling-time&- steady state error. Settling time is lowered to 2s and steady-state error in speed is also reduced to 1.98rpm in Sliding Mode (SM) control. The consequence denotes the-better outcomes of Closed- loop-Quadratic-BC-TPIS fed PMSMD with SM controller.

Authors

Institutions

Publication Details

Journal
REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE
Published
2025-08-30
DOI
https://doi.org/10.59277/rrst-ee.2025.3.8
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SLIDING MODE CONTROLLED CLOSED LOOP QB-CONVERTER -TPIS FED PMSM DRIVE WITH ENHANCED RESPONSE

A. Sivaprakasam, BHAVANI SOMASUNDARAM
REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE
Advanced DC-DC Converters
article

SLIDING MODE CONTROLLED CLOSED LOOP QB-CONVERTER -TPIS FED PMSM DRIVE WITH ENHANCED RESPONSE

A. Sivaprakasam, BHAVANI SOMASUNDARAM
article en

Abstract

The primary goal of this work is to identify the most appropriate controller for a QBC-TPIS fed PMSMD used high performance drives. A drive requires fast dynamic response and accurate control for its operation. This effort deals with the design, analysis &simulation of Closed loop- Quadratic Boost (QB) Converter-TPIS (Three Phase Inverter System) fed PMSM (Permanent Magnet Synchronous Motors) with Proportional-Integral (PI) & SM (Sliding mode) controller outcomes are presented. In this work duty cycle optimization of Q-Boost Converter was done by control input of SM controller. The-consequences are related in terms of-time-domain aspects like –rise-time,-peak-time,-settling-time&- steady state error. Settling time is lowered to 2s and steady-state error in speed is also reduced to 1.98rpm in Sliding Mode (SM) control. The consequence denotes the-better outcomes of Closed- loop-Quadratic-BC-TPIS fed PMSMD with SM controller.

REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUEVol. 70(3)
Anna University, Chennai (IN), Sri Ramachandra Medical Centre (IN)
Openalex Percentile: Top 78%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.