DYNAMIC BEHAVIOR ANALYSIS OF LOAD FREQUENCY CONTROL IN POWER SYSTEMS WITH HYBRID POWER PLANTS

In power systems, maintaining a nearly constant frequency is essential for stable operation. The secondary control loop plays a crucial role in regulating the system frequency, ensuring it remains at or near its nominal value. Additionally, this control loop is responsible for maintaining the scheduled power exchange between interconnected control areas via tie lines. This study focuses on analyzing and simulating the dynamic response of interconnected power systems under various configurations. The examined power system areas include steam, hydroelectric, and gas power plants. MATLAB-based simulations are conducted on both two-area and three-area power system models. The time-domain simulation results are further evaluated through eigenvalue analysis of the system matrix under different operating conditions. The findings indicate that, following a step change in load demand within isolated areas, gas power plants exhibit the smallest frequency deviation (droop). In contrast, hydroelectric plants demonstrate the largest frequency droop. Additionally, gas power plants exhibit fewer changes in response to load changes compared to the other two types of generation sources.

Authors

Institutions

Publication Details

Journal
REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE
Published
2025-08-30
DOI
https://doi.org/10.59277/rrst-ee.2025.3.7
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DYNAMIC BEHAVIOR ANALYSIS OF LOAD FREQUENCY CONTROL IN POWER SYSTEMS WITH HYBRID POWER PLANTS

Ghazanfar Shahgholian
REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE
Frequency Control in Power Systems
article

DYNAMIC BEHAVIOR ANALYSIS OF LOAD FREQUENCY CONTROL IN POWER SYSTEMS WITH HYBRID POWER PLANTS

Ghazanfar Shahgholian
article en

Abstract

In power systems, maintaining a nearly constant frequency is essential for stable operation. The secondary control loop plays a crucial role in regulating the system frequency, ensuring it remains at or near its nominal value. Additionally, this control loop is responsible for maintaining the scheduled power exchange between interconnected control areas via tie lines. This study focuses on analyzing and simulating the dynamic response of interconnected power systems under various configurations. The examined power system areas include steam, hydroelectric, and gas power plants. MATLAB-based simulations are conducted on both two-area and three-area power system models. The time-domain simulation results are further evaluated through eigenvalue analysis of the system matrix under different operating conditions. The findings indicate that, following a step change in load demand within isolated areas, gas power plants exhibit the smallest frequency deviation (droop). In contrast, hydroelectric plants demonstrate the largest frequency droop. Additionally, gas power plants exhibit fewer changes in response to load changes compared to the other two types of generation sources.

REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUEVol. 70(3)
Islamic Azad University of Najafabad (IR)
Openalex Percentile: Top 78%
Frequency Control in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.