Physical principles adapted to clinical practice for a theoretical smoke evacuation device in laparoscopic surgery

Suboptimal visualization of the surgical field due to smoke generated in any laparoscopic technique, along with the impact on healthcare workers exposed to its toxic particles, has prompted the marketing of various suctioning devices. A limited information on physical basis of these systems has encouraged us to develop a theoretical model that enables a basic experimental recreation of smoke evacuation in pneumoperitoneum. The cooling effect of the abdominal cavity due to the circulation of insufflated gas and variations in its composition resulting from the operative use of electrocoagulation are the primary factors that lead to the collapse of a circuit designed under laminar flow conditions when an increase in suction flow rate is required to preserve surgical vision. The pressure difference generated in the circuit by tripling its flow induces a change in flow regime, preventing collapse without the need for excessive gas renewal. An analysis of the cross-sectional radius, tube wall composition and absolute roughness of endoluminal surface are conducted to assess performance of our model. Behavior of fluids in different pathophysiological situations is studied by Science undergraduates, but instructional simulations in the laboratory often fail to transfer this knowledge into the design of practical devices that correlate the statics of an inert material with the variability of a biological system. This theoretical device has been crafted to encourage students interested in the experimental patterns for biomedical applications related to fluid behavior and turnover during minimally invasive procedures involving the peritoneal cavity.

Authors

Institutions

Publication Details

Journal
Revista Mexicana de Física
Published
2025-09-01
DOI
https://doi.org/10.31349/revmexfis.71.051101
Primary Topic
Body Contouring and Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Physical principles adapted to clinical practice for a theoretical smoke evacuation device in laparoscopic surgery

Victor J Ovejero, Victor Jacinto Ovejero, Cristina Sainz
Revista Mexicana de Física
Body Contouring and Surgery
article

Physical principles adapted to clinical practice for a theoretical smoke evacuation device in laparoscopic surgery

Victor J Ovejero, Victor Jacinto Ovejero, Cristina Sainz
article en

Abstract

Suboptimal visualization of the surgical field due to smoke generated in any laparoscopic technique, along with the impact on healthcare workers exposed to its toxic particles, has prompted the marketing of various suctioning devices. A limited information on physical basis of these systems has encouraged us to develop a theoretical model that enables a basic experimental recreation of smoke evacuation in pneumoperitoneum. The cooling effect of the abdominal cavity due to the circulation of insufflated gas and variations in its composition resulting from the operative use of electrocoagulation are the primary factors that lead to the collapse of a circuit designed under laminar flow conditions when an increase in suction flow rate is required to preserve surgical vision. The pressure difference generated in the circuit by tripling its flow induces a change in flow regime, preventing collapse without the need for excessive gas renewal. An analysis of the cross-sectional radius, tube wall composition and absolute roughness of endoluminal surface are conducted to assess performance of our model. Behavior of fluids in different pathophysiological situations is studied by Science undergraduates, but instructional simulations in the laboratory often fail to transfer this knowledge into the design of practical devices that correlate the statics of an inert material with the variability of a biological system. This theoretical device has been crafted to encourage students interested in the experimental patterns for biomedical applications related to fluid behavior and turnover during minimally invasive procedures involving the peritoneal cavity.

Revista Mexicana de FísicaVol. 71(5 Sep-Oct)
Universidad de Cantabria (ES)
Openalex Percentile: Top 63%
Body Contouring and Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Physical principles adapted to clinical practice for a theoretical smoke evacuation device in laparoscopic surgery — Victor J Ovejero, Victor Jacinto Ovejero, et al. · Revista Mexicana de Física (2025) | TGRS Research Map | TGRS