Implantable Cardioverter–Defibrillator Therapies Following Generator Replacements—Long-Term Remote Monitoring Data
<b>Background</b>: The rate of long-term outcomes, including arrhythmic episodes following implantable cardioverter-defibrillator (ICD) device replacements, is often unknown. Thus, the aim of this manuscript was to evaluate the risk of ICD or cardiac resynchronization therapy-defibrillator (CRT-D) therapies in remotely monitored patients following device replacement. <b>Methods</b>: Data from 134 patients who underwent ICD/CRT-D replacement or upgrade were analyzed. Kaplan-Meier estimates, as well as Cox proportional hazards regression, were used to present long-term outcomes and predictors of study endpoints, these being all-cause mortality, and appropriate and inappropriate ICD/CRT-D therapies. <b>Results</b>: Among the cohort, 51.5% of patients received ICDs and 48.5% received CRT-Ds; the median (quartile 1-quartile 3) LVEF at replacement was 23.0% (18.0-28.0%). In 11 (8.2%) patients, the LVEF at replacement was higher than 35%. During the median (Q1-Q3) follow-up of 3.0 (1.4-5.0) years, 32.1% experienced appropriate and 6.0% experienced inappropriate therapies. The all-cause mortality rate was 38.0%, and appropriate antitachycardia pacing (ATP), a reduced baseline LVEF, and no history of myocardial infarction were independent predictors of death (odds ratios of 1.87 for appropriate ATP, 0.88 per 1% of the LVEF and 0.54 for a history of MI, respectively). The rate of appropriate device therapies was numerically lower in patients whose LVEF improved (19.8% vs. 33.3% and 0% vs. 6.5%, for appropriate and inappropriate therapies). An LVEF of >35% at replacement did not influence the analyzed outcomes. <b>Conclusions</b>: In patients who underwent ICD/CRT-D replacement, an improvement in LVEF was not identified as either a predictor of improved survival or of a lower risk of needing device therapies. Further stratification models are needed to evaluate the arrhythmic risk in patients after generator replacements.
Authors
- Elżbieta Adamowicz‐Czoch
- Anna Kurek
- Joanna Machowicz (ORCID: https://orcid.org/0000-0002-0768-931X)
- Mariusz Gąsior (ORCID: https://orcid.org/0000-0001-6775-1392)
- Jacek Niedziela (ORCID: https://orcid.org/0000-0001-5016-8862)
- Maciej Dyrbuś (ORCID: https://orcid.org/0000-0002-2506-2430)
- Michał Skrzypek (ORCID: https://orcid.org/0000-0003-3410-7407)
- Łukasz Pyka (ORCID: https://orcid.org/0000-0002-7292-2827)
- Mateusz Ostręga
- Katarzyna Sokoła
- Mateusz Tajstra (ORCID: https://orcid.org/0000-0003-4145-5485)
- Damian Pres
Institutions
- Medical University of Silesia (PL)
- Wojewódzki Szpital Specjalistyczny nr 4 w Bytomiu (PL)
Publication Details
- Journal
- Clinics and Practice
- Published
- 2025-08-30
- DOI
- https://doi.org/10.3390/clinpract15090160
- Primary Topic
- Cardiac pacing and defibrillation studies
- Type
- article
- Field-Weighted Citation Impact
- 0.00