Implementation of Customized Homogenizing Devices in Radiotherapy for the Treatment of Non-Melanoma Skin Cancer: Three Case Reports

<b>Background and Clinical Significance</b>: In most cases, the success of radiotherapy in the treatment for skin cancer is limited, particularly due to the irregularities of the neoplasm's surfaces or even tissue discontinuity. Based on a comprehensive clinical assessment, the therapeutic approach for radiotherapy was established for the patients included in this study. Wax-paraffin (50:50) devices were custom-designed for radiotherapy treatment, confirming adequate homogeneity and conformity indices for doses of 55-66 Gy, and chemotherapy when necessary. Toxicity and treatment response were also assessed; <b>Cases Presentation</b>: For patient 1, two lesions located on the right nasolabial fold and right thigh were treated with radiation, and a 1 cm thick wax-paraffin surface bolus was designed, allowing for improved dose distribution and favorable local response. For patient 2, in addition to the thick wax-paraffin homogenizer, lead eye protectors were designed due to the location of the tumor, with the aim of protecting organs at risk. The treatment in this patient resulted in effective local response. Finally, for patient 3, with a lesion in the supraclavicular region extending to the left shoulder due to acantholytic squamous cell carcinoma with secondary carcinomatous lymphangitis, 1 cm thick wax-paraffin surface homogenizers were used; <b>Conclusions</b>: Due to the characteristics of the customized homogenizers, tumor lesion remission was successfully achieved in all three patients, highlighting both the advantages of these devices and their efficacy in dose distribution and local response in radiotherapy treatment of non-melanoma skin carcinoma.

Authors

Institutions

Publication Details

Journal
Reports — Medical Cases Images and Videos
Published
2025-09-01
DOI
https://doi.org/10.3390/reports8030165
Primary Topic
Nonmelanoma Skin Cancer Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementation of Customized Homogenizing Devices in Radiotherapy for the Treatment of Non-Melanoma Skin Cancer: Three Case Reports

J. Cano Velasco, Carlos Alberto Castro-Fuentes, Alejandro Chagoya González, K Hernández et al.
Reports — Medical Cases Images and Videos
Nonmelanoma Skin Cancer Studies
article

Implementation of Customized Homogenizing Devices in Radiotherapy for the Treatment of Non-Melanoma Skin Cancer: Three Case Reports

J. Cano Velasco, Carlos Alberto Castro-Fuentes, Alejandro Chagoya González, K Hernández, Rosa Marene Hernández Martínez
article en

Abstract

<b>Background and Clinical Significance</b>: In most cases, the success of radiotherapy in the treatment for skin cancer is limited, particularly due to the irregularities of the neoplasm's surfaces or even tissue discontinuity. Based on a comprehensive clinical assessment, the therapeutic approach for radiotherapy was established for the patients included in this study. Wax-paraffin (50:50) devices were custom-designed for radiotherapy treatment, confirming adequate homogeneity and conformity indices for doses of 55-66 Gy, and chemotherapy when necessary. Toxicity and treatment response were also assessed; <b>Cases Presentation</b>: For patient 1, two lesions located on the right nasolabial fold and right thigh were treated with radiation, and a 1 cm thick wax-paraffin surface bolus was designed, allowing for improved dose distribution and favorable local response. For patient 2, in addition to the thick wax-paraffin homogenizer, lead eye protectors were designed due to the location of the tumor, with the aim of protecting organs at risk. The treatment in this patient resulted in effective local response. Finally, for patient 3, with a lesion in the supraclavicular region extending to the left shoulder due to acantholytic squamous cell carcinoma with secondary carcinomatous lymphangitis, 1 cm thick wax-paraffin surface homogenizers were used; <b>Conclusions</b>: Due to the characteristics of the customized homogenizers, tumor lesion remission was successfully achieved in all three patients, highlighting both the advantages of these devices and their efficacy in dose distribution and local response in radiotherapy treatment of non-melanoma skin carcinoma.

Reports — Medical Cases Images and VideosVol. 8(3)
Mexican Social Security Institute (MX), Hospital de Especialidades (MX), Hospital Regional de Alta Especialidad del Bajío (MX)
Openalex Percentile: Top 68%
Nonmelanoma Skin Cancer Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.