Active time-reversal based phased array ultrasound system for accurate focusing through biological tissue layers

Ultrasonic phased array technology enables flexible and controllable beamforming through precise phase delay control of individual array elements in the transducer, facilitating dynamic focusing, beam steering, and beamforming. This study presents a 64-channel system achieving 1 ns delay resolution using FPGA-based phase-locked loops. Through systematic testing and calibration of the delay error in the phased array transmission driving system, the actual delay error was successfully controlled within 1 ns. Furthermore, to address the focal shift issue in multi-layer soft tissues, this research implemented active time reversal and phase compensation methods for focal shift correction. Experimental results demonstrate that the proposed system not only exhibits excellent driving and phase modulation capabilities but also effectively reduces tissue-induced focal shift.

Authors

Institutions

Publication Details

Journal
Discover Nano
Published
2025-09-01
DOI
https://doi.org/10.1186/s11671-025-04331-6
Primary Topic
Ultrasonics and Acoustic Wave Propagation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Active time-reversal based phased array ultrasound system for accurate focusing through biological tissue layers

Hui‐Xiong Xu, Xuexin Gao, Xiaojing He, WeiJuan Chen et al.
Discover Nano
Ultrasonics and Acoustic Wave Propagation
article

Active time-reversal based phased array ultrasound system for accurate focusing through biological tissue layers

Hui‐Xiong Xu, Xuexin Gao, Xiaojing He, WeiJuan Chen, So Yung Yang, Qi Lai
article en

Abstract

Ultrasonic phased array technology enables flexible and controllable beamforming through precise phase delay control of individual array elements in the transducer, facilitating dynamic focusing, beam steering, and beamforming. This study presents a 64-channel system achieving 1 ns delay resolution using FPGA-based phase-locked loops. Through systematic testing and calibration of the delay error in the phased array transmission driving system, the actual delay error was successfully controlled within 1 ns. Furthermore, to address the focal shift issue in multi-layer soft tissues, this research implemented active time reversal and phase compensation methods for focal shift correction. Experimental results demonstrate that the proposed system not only exhibits excellent driving and phase modulation capabilities but also effectively reduces tissue-induced focal shift.

Discover NanoVol. 20(1)
Dalian Medical University (CN), Second Affiliated Hospital of Chongqing Medical University (CN), Chongqing Maternal and Child Health Hospital (CN), Children's Hospital of Chongqing Medical University (CN), Chongqing Medical University (CN)
Openalex Percentile: Top 74%
Ultrasonics and Acoustic Wave Propagation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.