Comparison of Low‐Rank Denoising Methods for Dynamic Deuterium MRSI at 7 T
Dynamic deuterium (<sup>2</sup>H)-MRSI enables mapping of metabolic fluxes in vivo, but its sensitivity is hampered by the low <sup>2</sup>H gyromagnetic ratio and <sup>2</sup>H-labelled metabolite concentrations. Low-rank denoising can enhance MRSI sensitivity by separating signal from noise. Several methods have been proposed, but the optimal approach for dynamic <sup>2</sup>H-MRSI remains unclear. This work compares six low-rank denoising methods for dynamic <sup>2</sup>H-MRSI: four variations of spatiospectral partial separability (PS)-Global PS, Local PS, Stacked PS and SPectral and temporal INtegration for SVD (SPIN-SVD)-as well as global-local higher order singular value decomposition (GL-HOSVD) and tensor Marchenko-Pastur principal component analysis (tMPPCA). Performance was evaluated using realistic <sup>2</sup>H-MRSI brain simulations across a range of noise and B<sub>0</sub> inhomogeneity levels, including a lesion model featuring focal metabolic alteration, and in vivo data. For simulations at the in vivo SNR and B<sub>0</sub> level, the concentration root-mean-square errors (RMSE) of the fitted metabolite maps against gold standard maps were reduced by 29.3%, 24.4%, 20.2%, 33.4%, 23.5% and 21.9% following denoising with Global PS, Local PS, Stacked PS, SPIN-SVD, GL-HOSVD and tMPPCA, respectively. Across all simulated noise levels and all but the highest B<sub>0</sub> inhomogeneity level, SPIN-SVD achieved the lowest concentration RMSE and best preserved spatial distributions of <sup>2</sup>H-labelled water (HDO) and lactate (Lac), including lesion-associated changes. While Global PS and Stacked PS reduced noise variance, they failed to preserve signal variations in simulated and in vivo data. SPIN-SVD, GL-HOSVD and tMPPCA reduced noise in vivo while maintaining spatial and temporal metabolite variations. GL-HOSVD and tMPPCA performed similarly, with tMPPCA preferred for its computational efficiency. Both SPIN-SVD and tMPPCA are suitable for denoising dynamic <sup>2</sup>H-MRSI, with SPIN-SVD preferable for clinical applications owing to its simple implementation and superior preservation of local metabolic alterations, and tMPPCA better suited for absolute quantification of very low SNR metabolites.
Authors
- Korbinian Eckstein (ORCID: https://orcid.org/0000-0002-4538-7072)
- Wolfgang Bogner (ORCID: https://orcid.org/0000-0002-0130-3463)
- Lukas Hingerl (ORCID: https://orcid.org/0000-0003-1808-8349)
- Simon Robinson (ORCID: https://orcid.org/0000-0001-7463-5162)
- Bernard Lanz (ORCID: https://orcid.org/0000-0001-5136-075X)
- Fabian Niess (ORCID: https://orcid.org/0000-0003-1235-7595)
- Bernhard Strasser (ORCID: https://orcid.org/0000-0001-9542-3855)
- Cristina Cudalbu (ORCID: https://orcid.org/0000-0003-4582-2465)
- Anna Duguid (ORCID: https://orcid.org/0009-0003-7044-3165)
- Viola Bader (ORCID: https://orcid.org/0009-0004-2393-9579)
- Brayan Alves
- S.D. Frese
- Aaron Osburg (ORCID: https://orcid.org/0009-0001-2622-3355)
Institutions
- Christian Doppler Laboratory for Thermoelectricity (AT)
- Centre d'Imagerie BioMedicale (CH)
- École Polytechnique Fédérale de Lausanne (CH)
- Medical University of Vienna (AT)
Publication Details
- Journal
- NMR in Biomedicine
- Published
- 2025-08-31
- DOI
- https://doi.org/10.1002/nbm.70125
- Citations
- 4
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 5.44
Funders
- European Commission
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
- Austrian Science Fund
- Christian Doppler Forschungsgesellschaft