Implementing tile-based fisher ratio analysis of two-dimensional gas chromatography time-of-flight mass spectrometry data to obtain a master peak table of all detected analyte compounds in many petroleum-based samples

• Tile-based Fisher-ratio analysis captures all analytes and is resilient to retention time shifting • Instrumental blanks are used for p-testing of detected analyte peaks across samples • The combination of F-ratio analysis with p-testing facilitates the creation of a Master Peak Table • The Master Peak Table enables the generation of inherently aligned sample-specific peak tables • Simulated-distillation curves are readily generated for each sample Historically, tile-based Fisher ratio (F-ratio) analysis of comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC-TOFMS) data was developed for analysts to use a supervised experimental design with defined sample classes to obtain a hit list to discover analytes that most significantly distinguish the sample classes at the top of the hit list. In this traditional application, a user-specified F-ratio threshold is used to discard most hits in order to focus on the top hits. To broaden the scope of tile-based F-ratio analysis, in the present study we explore the ability of the software to discover all analyte components that are detected in a set of samples, essentially taking full advantage of the tiling aspect of the software which uncovers all analytes that exhibit sufficient signal relative to the baseline noise across all samples to be deemed detectable and hence to produce an F-ratio. For this study a set of nine petroleum samples, i.e., two hydrobates (light naphthas), two reformates, four naphthas, and a “heavy” gasoline, are simultaneously analyzed and statistically compared via p-testing to blank chromatograms to produce one comprehensive hit list. The pin locations and signal areas at the top m/z F-ratio are used together with replicate blanks to generate a master peak table (MPT) that in turn is used to generate sample-specific peak tables (SSPT), one SSPT for each injection replicate of each petroleum sample (class), that are naturally retention-time aligned via the F-ratio software. The nine petroleum samples vary to a large extent in the identity and number of analytes present. Indeed, while a total of ∼715 analytes were found across all nine samples, only ∼260 of these analytes are fully shared across all sample classes. The number of analytes in the nine petroleum samples ranged from an average of 335 analytes for one of the hydrobates to 669 analytes for two of the naphthas. This workflow also facilitated generating simulated distillation curves for the nine petroleum samples to provide further insight.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography Open
Published
2025-08-31
DOI
https://doi.org/10.1016/j.jcoa.2025.100249
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementing tile-based fisher ratio analysis of two-dimensional gas chromatography time-of-flight mass spectrometry data to obtain a master peak table of all detected analyte compounds in many petroleum-based samples

Robert E. Synovec, Caitlin N. Cain, H. R. Ingham, Rachel E. Mohler et al.
Journal of Chromatography Open
Analytical Chemistry and Chromatography
article

Implementing tile-based fisher ratio analysis of two-dimensional gas chromatography time-of-flight mass spectrometry data to obtain a master peak table of all detected analyte compounds in many petroleum-based samples

Robert E. Synovec, Caitlin N. Cain, H. R. Ingham, Rachel E. Mohler, Wenjing Ma, R Halvorsen
article en

Abstract

• Tile-based Fisher-ratio analysis captures all analytes and is resilient to retention time shifting • Instrumental blanks are used for p-testing of detected analyte peaks across samples • The combination of F-ratio analysis with p-testing facilitates the creation of a Master Peak Table • The Master Peak Table enables the generation of inherently aligned sample-specific peak tables • Simulated-distillation curves are readily generated for each sample Historically, tile-based Fisher ratio (F-ratio) analysis of comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC-TOFMS) data was developed for analysts to use a supervised experimental design with defined sample classes to obtain a hit list to discover analytes that most significantly distinguish the sample classes at the top of the hit list. In this traditional application, a user-specified F-ratio threshold is used to discard most hits in order to focus on the top hits. To broaden the scope of tile-based F-ratio analysis, in the present study we explore the ability of the software to discover all analyte components that are detected in a set of samples, essentially taking full advantage of the tiling aspect of the software which uncovers all analytes that exhibit sufficient signal relative to the baseline noise across all samples to be deemed detectable and hence to produce an F-ratio. For this study a set of nine petroleum samples, i.e., two hydrobates (light naphthas), two reformates, four naphthas, and a “heavy” gasoline, are simultaneously analyzed and statistically compared via p-testing to blank chromatograms to produce one comprehensive hit list. The pin locations and signal areas at the top m/z F-ratio are used together with replicate blanks to generate a master peak table (MPT) that in turn is used to generate sample-specific peak tables (SSPT), one SSPT for each injection replicate of each petroleum sample (class), that are naturally retention-time aligned via the F-ratio software. The nine petroleum samples vary to a large extent in the identity and number of analytes present. Indeed, while a total of ∼715 analytes were found across all nine samples, only ∼260 of these analytes are fully shared across all sample classes. The number of analytes in the nine petroleum samples ranged from an average of 335 analytes for one of the hydrobates to 669 analytes for two of the naphthas. This workflow also facilitated generating simulated distillation curves for the nine petroleum samples to provide further insight.

Journal of Chromatography OpenVol. 8
University of Washington (US), Chevron (United States) (US)
Openalex Percentile: Top 79%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.