A novel two-phase quality measurement technique using vortex frequencies in fluid flows
• Demonstrated novel use of vortex frequency to calculate quality in fluid flows. • Validated findings through a controlled two-phase experimental test facility. • Proved the advantages of frequency-based regression hypothesis. • Resulted in excellent correlation (R 2 ∼ 0.97) across quality (0.91 to 0.51) • Offers low-cost, real-time solution with practical implications for diagnostics. Accurate two-phase measurement has the potential to unlock new capabilities in energy conversion and control. Measuring real-time quality remains a problem due to the complex, non-linear interaction between the phases. Conventional methods often rely on intrusive or multi-point instrumentation, limiting their suitability for compact or embedded applications. This study offers a solution by presenting a novel method for estimating steam quality using vortex shedding frequencies from a flow meter. A dedicated test facility was developed to evaluate the approach, maintaining a fixed 30 kg/hr mass flow rate, at pressures 1.2–1.6 bar, and quality 0.91–0.51. During exploratory testing, vortex frequency showed two distinct bands, suggesting the presence of two mediums. This presented a method from which four different hypotheses were assessed: (1) a midpoint threshold between distinctive vapour and liquid frequency bands, (2) a fixed frequency cut-off at the onset of the liquid peak, (3) a kurtosis-based regression model, and (4) a linear regression based on the mean vortex frequency. The first three methods demonstrated limited or inconsistent accuracy. The fourth method, demonstrating the impact of this work, yielded results that indicated a strong correlation with true vapour quality with R 2 ∼ 0.97, validated against repeatable condensate mass measurements with accuracy in vapour quality of ± 0.02. These results confirm that frequency signals typically used for volumetric flow, can be uniquely repurposed as indicators of phase composition. The contribution of this approach lies in enabling real-time quality monitoring in systems requiring the measurement and control of two-phase flows.
Authors
- Angad Singh Panesar (ORCID: https://orcid.org/0000-0001-9000-4854)
- I.J. Kemp (ORCID: https://orcid.org/0000-0002-6637-9987)
Institutions
- University of Brighton (GB)
Publication Details
- Journal
- Measurement
- Published
- 2025-08-31
- DOI
- https://doi.org/10.1016/j.measurement.2025.118876
- Primary Topic
- Flow Measurement and Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00