omparison of CSMC (Cedar Sinai Medical Center) QGS/QPS (Quantitative Gated SPECT/Quantitative Perfusion SPECT) and INVIA-4 Dimension Myocardial SPECT Softwares for Quantitative Analysis of Left Ventricular Perfusion and Function in Gated Myocardial S

Objective: To compare left ventricular parameters using Quantitative Perfusion SPECT / Quantitative Gated SPECT (QPS / QGS) and 4 Dimension-Myocardial SPECT (4-DM) softwares. Study Designs: Analytical Cross Sectional study Place and Duration of Study: Nuclear Medical Centre, Armed Forces Institute of Pathology Rawalpindi, Pakistan from Jun 2022 to Jun 2023. Methodology: One hundred and thirty seven patients with suspicion of coronary artery disease underwent myocardial perfusion scan during study duration. The patients underwent stress and rest gated SPECT imaging using a single day protocol. All the images were processed using QGS / QPS and 4-DM softwares separately and left ventricular parameters including Summed Stress Score (SSS), Summed Rest Score (SRS), Summed Difference Score (SDS), End Diastolic Volume (EDV), End Systolic Volume (ESV) and Ejection Fraction (EF) were calculated. Mean values and relationship between both softwares were calculated. Results: Out of 137 patients, 80(58.4%) were men and 57(41.6%) were women with mean age of 56.29±15.17 years. The mean SSS, SRS, SDS, EDV, ESV and EF by QGS was 9.83±8.08, 6.24±6.01, 2.54±2.18, 93.94±42.73 ml, 48.04±38.16 ml and 55.94±18.06 %. While by 4-DM was 9.07±7.41, 6.72±6.39, 2.84±2.51, 97.64±43.46 ml, 45.02±40.29 ml, 61.59±18.36 % respectively. All the left ventricular parameters including SSS, SRS, SDS, EDV, ESV and EF as measured by both softwares showed substantial variation with a p-value of <0.001 suggesting significance statistical difference. Conclusions: The left ventricular parameters assessed by both softwares differ significantly, so both softwares should not be used interchangeably for a single patient.

Authors

Institutions

Publication Details

Journal
Pakistan Armed Forces Medical Journal
Published
2025-08-30
DOI
https://doi.org/10.51253/pafmj.v75i4.10764
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

omparison of CSMC (Cedar Sinai Medical Center) QGS/QPS (Quantitative Gated SPECT/Quantitative Perfusion SPECT) and INVIA-4 Dimension Myocardial SPECT Softwares for Quantitative Analysis of Left Ventricular Perfusion and Function in Gated Myocardial S

Muhammad Adil, Asad Malik, Zeeshan Sikandar, Muhammad Atif et al.
Pakistan Armed Forces Medical Journal
Cardiac Imaging and Diagnostics
article

omparison of CSMC (Cedar Sinai Medical Center) QGS/QPS (Quantitative Gated SPECT/Quantitative Perfusion SPECT) and INVIA-4 Dimension Myocardial SPECT Softwares for Quantitative Analysis of Left Ventricular Perfusion and Function in Gated Myocardial S

Muhammad Adil, Asad Malik, Zeeshan Sikandar, Muhammad Atif, Fida Hussain, Hafiza Shameela
article en

Abstract

Objective: To compare left ventricular parameters using Quantitative Perfusion SPECT / Quantitative Gated SPECT (QPS / QGS) and 4 Dimension-Myocardial SPECT (4-DM) softwares. Study Designs: Analytical Cross Sectional study Place and Duration of Study: Nuclear Medical Centre, Armed Forces Institute of Pathology Rawalpindi, Pakistan from Jun 2022 to Jun 2023. Methodology: One hundred and thirty seven patients with suspicion of coronary artery disease underwent myocardial perfusion scan during study duration. The patients underwent stress and rest gated SPECT imaging using a single day protocol. All the images were processed using QGS / QPS and 4-DM softwares separately and left ventricular parameters including Summed Stress Score (SSS), Summed Rest Score (SRS), Summed Difference Score (SDS), End Diastolic Volume (EDV), End Systolic Volume (ESV) and Ejection Fraction (EF) were calculated. Mean values and relationship between both softwares were calculated. Results: Out of 137 patients, 80(58.4%) were men and 57(41.6%) were women with mean age of 56.29±15.17 years. The mean SSS, SRS, SDS, EDV, ESV and EF by QGS was 9.83±8.08, 6.24±6.01, 2.54±2.18, 93.94±42.73 ml, 48.04±38.16 ml and 55.94±18.06 %. While by 4-DM was 9.07±7.41, 6.72±6.39, 2.84±2.51, 97.64±43.46 ml, 45.02±40.29 ml, 61.59±18.36 % respectively. All the left ventricular parameters including SSS, SRS, SDS, EDV, ESV and EF as measured by both softwares showed substantial variation with a p-value of <0.001 suggesting significance statistical difference. Conclusions: The left ventricular parameters assessed by both softwares differ significantly, so both softwares should not be used interchangeably for a single patient.

Pakistan Armed Forces Medical JournalVol. 75(4)
National University of Medical Sciences (PK)
Openalex Percentile: Top 68%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.