Wearable Coil Using Copper Traces on Fabric for MRI at 3T

<bold xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Objectives:</b> Conductors used for fabrication of coils on fabric substrates suffer from inherent losses because of the combination of the metallic core with other non-conductive materials, thus limiting the SNR achieved. The purpose of this work is to demonstrate the application of copper traces on a fabric substrate to reduce conductor losses experienced in wearable coils. <bold xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Methods:</b> A single channel coil was developed from a copper sheet using a cutting plotter. The coil was loaded onto a spherical phantom to evaluate the SNR when compared with standard rigid and flexible PCB based coils. A nine-channel wearable array was developed for structural and kinematic imaging of the shoulder at 3T. The SNR from the phantom and in vivo images was compared with a commercial flexible coil. <bold xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Results:</b> The single channel coil provided 2.1 times the SNR of the rigid PCB coil and 1.2 times the SNR of the flexible PCB coil. Image acquisition using the shoulder array can be accelerated twice or thrice in the left-right or superior-inferior directions. The shoulder array provided a 12.1% increase in SNR than the commercial array from phantom imaging. The wearable shoulder array provided an 10.5% increase in average SNR when compared to the commercial coil across 2D and 3D in vivo images. <bold xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Clinical Impact:</b> The application of copper traces directly on fabric provides a new outlook toward the development of wearable coils by eliminating inherent conductor losses to improve the image quality for musculoskeletal MRI.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology
Published
2025-08-29
DOI
https://doi.org/10.1109/jerm.2025.3599743
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable Coil Using Copper Traces on Fabric for MRI at 3T

Thejas Vishnu Ramesh, Joseph V. Rispoli
IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology
Advanced MRI Techniques and Applications
article

Wearable Coil Using Copper Traces on Fabric for MRI at 3T

Thejas Vishnu Ramesh, Joseph V. Rispoli
article en

Abstract

<bold xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Objectives:</b> Conductors used for fabrication of coils on fabric substrates suffer from inherent losses because of the combination of the metallic core with other non-conductive materials, thus limiting the SNR achieved. The purpose of this work is to demonstrate the application of copper traces on a fabric substrate to reduce conductor losses experienced in wearable coils. <bold xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Methods:</b> A single channel coil was developed from a copper sheet using a cutting plotter. The coil was loaded onto a spherical phantom to evaluate the SNR when compared with standard rigid and flexible PCB based coils. A nine-channel wearable array was developed for structural and kinematic imaging of the shoulder at 3T. The SNR from the phantom and in vivo images was compared with a commercial flexible coil. <bold xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Results:</b> The single channel coil provided 2.1 times the SNR of the rigid PCB coil and 1.2 times the SNR of the flexible PCB coil. Image acquisition using the shoulder array can be accelerated twice or thrice in the left-right or superior-inferior directions. The shoulder array provided a 12.1% increase in SNR than the commercial array from phantom imaging. The wearable shoulder array provided an 10.5% increase in average SNR when compared to the commercial coil across 2D and 3D in vivo images. <bold xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Clinical Impact:</b> The application of copper traces directly on fabric provides a new outlook toward the development of wearable coils by eliminating inherent conductor losses to improve the image quality for musculoskeletal MRI.

IEEE Journal of Electromagnetics RF and Microwaves in Medicine and BiologyVol. 9(4)
Purdue University West Lafayette (US), University of Virginia (US)
Openalex Percentile: Top 68%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.