Comparative Analysis of Thermoplastic and Resin-Laminated PTBSC Sockets on Quadriceps Muscle Profile in a Transtibial Amputee: A Case Study

Background: Socket design and material significantly affect comfort, function, and muscle engagement in transtibial prosthetic users. This case study compares the influence of thermoplastic and resin-laminated PTBSC (Patellar Tendon Bearing Supracondylar) sockets on the quadriceps muscle profile of a transtibial amputee using surface electromyography (sEMG). Methods: A 32-year-old male with a right-sided transtibial amputation was fitted with two prosthetic sockets—first with a thermoplastic PTBSC socket and then with a resin-laminated PTBSC socket. Each was worn for three months. EMG activity of the rectus femoris muscle was recorded during controlled knee extension using a surface EMG system. The average of three trials was calculated for each condition. Results: Mean quadriceps muscle activity for the thermoplastic socket was 0.5467 ± 0.08910, and for the resin-laminated socket, 0.5853 ± 0.08717. No statistically significant difference in muscle activity was observed. However, the patient subjectively reported better comfort, reduced weight, and ease of use with the resin-laminated socket. Conclusion: Both socket types provided comparable biomechanical support as reflected in muscle activity. The resin-laminated socket, while not superior in EMG performance, was preferred by the user due to better subjective comfort and usability. These findings suggest that socket material selection should consider both functional and user-centered factors to optimize prosthetic outcomes. Further research with larger samples is warranted. Keywords: Transtibial Amputation, PTBSC Socket, Thermoplastic Socket, Resin-Laminated Socket, Surface Electromyography (sEMG), Quadriceps Muscle Activity, Prosthetic Socket Design, Patient Satisfaction, Rehabilitation Engineering.

Authors

Institutions

Publication Details

Journal
International Journal of Science and Healthcare Research
Published
2025-08-29
DOI
https://doi.org/10.52403/ijshr.20250311
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of Thermoplastic and Resin-Laminated PTBSC Sockets on Quadriceps Muscle Profile in a Transtibial Amputee: A Case Study

Souvik Naskar, Sai Prabha Mishra, Dr Ameed Equebal, Prakash Kumar Sahoo et al.
International Journal of Science and Healthcare Research
Prosthetics and Rehabilitation Robotics
article

Comparative Analysis of Thermoplastic and Resin-Laminated PTBSC Sockets on Quadriceps Muscle Profile in a Transtibial Amputee: A Case Study

Souvik Naskar, Sai Prabha Mishra, Dr Ameed Equebal, Prakash Kumar Sahoo, Prasanna Lenka
article en

Abstract

Background: Socket design and material significantly affect comfort, function, and muscle engagement in transtibial prosthetic users. This case study compares the influence of thermoplastic and resin-laminated PTBSC (Patellar Tendon Bearing Supracondylar) sockets on the quadriceps muscle profile of a transtibial amputee using surface electromyography (sEMG). Methods: A 32-year-old male with a right-sided transtibial amputation was fitted with two prosthetic sockets—first with a thermoplastic PTBSC socket and then with a resin-laminated PTBSC socket. Each was worn for three months. EMG activity of the rectus femoris muscle was recorded during controlled knee extension using a surface EMG system. The average of three trials was calculated for each condition. Results: Mean quadriceps muscle activity for the thermoplastic socket was 0.5467 ± 0.08910, and for the resin-laminated socket, 0.5853 ± 0.08717. No statistically significant difference in muscle activity was observed. However, the patient subjectively reported better comfort, reduced weight, and ease of use with the resin-laminated socket. Conclusion: Both socket types provided comparable biomechanical support as reflected in muscle activity. The resin-laminated socket, while not superior in EMG performance, was preferred by the user due to better subjective comfort and usability. These findings suggest that socket material selection should consider both functional and user-centered factors to optimize prosthetic outcomes. Further research with larger samples is warranted. Keywords: Transtibial Amputation, PTBSC Socket, Thermoplastic Socket, Resin-Laminated Socket, Surface Electromyography (sEMG), Quadriceps Muscle Activity, Prosthetic Socket Design, Patient Satisfaction, Rehabilitation Engineering.

International Journal of Science and Healthcare ResearchVol. 10(3)
Indian Institute of Technology Guwahati (IN), National Institute of Technical Teachers’ Training and Research (IN), Colgate-Palmolive (India) (IN), National Institute of Pharmaceutical Education and Research (IN)
Openalex Percentile: Top 78%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.