Experimental and Analytical Study on Structural Behaviour of RC Beams Retrofitted with a Hybrid System of CFRP, GFRP, Mas Plates, and Concrete Jacketing

This study examines the flexural performance of reinforced concrete (RC) beams retrofitted with a first-time hybrid system comprising CFRP laminates, GFRP bars, mechanical anchorage plates, and concrete jacketing. Although similar retrofitting methods are increasingly adopted, detailed analyses in line with BS code provisions remain limited. The research addresses this gap through four-point bending tests, examining crack behaviour, failure modes, load–deflection behaviour, and comparisons between experimental results and analytical predictions based on BS code provisions. Five beams were used as controls and five beams used as the retrofitted beams. Beams A, B, C, and D shared a concrete compressive strength of 37.03 MPa, whereas beam E has a strength of 26.77 MPa. Tension reinforcement was varied between two 12 mm diameter bottom bars and three 12 mm bars. The ratio of the retrofitted beam to the unretrofitted beam ultimate loads were recorded as 140 %, 158 %, 154 %, 144 %, and 146 % for the beams A, B, C, D, and E respectively, indicating a significant increase as a result of the strengthening. A novel formula for estimating the flexural moment capacity of this first-time hybrid retrofitted beam is proposed and validated against experimental and analytical results. This novel combination of the hybrid retrofitting system significantly increased the flexural moment of the RC beam. The mean ratio of experimental to analytical moments is 0.94, with a variance of 0.00541, indicating strong agreement. The proposed novel hybrid retrofitting system and novel formula demonstrate high accuracy to the experimental results which helps to pre-empt the experimental moments before they are conducted. Also, the novel formula is suitable for application to beams with similar hybrid retrofitting configurations to significantly strengthen the flexural moment capacity of the RC beams.

Authors

Publication Details

Journal
Asian Journal of Advanced Research and Reports
Published
2025-08-30
DOI
https://doi.org/10.9734/ajarr/2025/v19i91141
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and Analytical Study on Structural Behaviour of RC Beams Retrofitted with a Hybrid System of CFRP, GFRP, Mas Plates, and Concrete Jacketing

Charles K. Kankam, Fredrick Ali Issifu, Michael Nii Sarbah Okine
Asian Journal of Advanced Research and Reports
Structural Behavior of Reinforced Concrete
article

Experimental and Analytical Study on Structural Behaviour of RC Beams Retrofitted with a Hybrid System of CFRP, GFRP, Mas Plates, and Concrete Jacketing

Charles K. Kankam, Fredrick Ali Issifu, Michael Nii Sarbah Okine
article en

Abstract

This study examines the flexural performance of reinforced concrete (RC) beams retrofitted with a first-time hybrid system comprising CFRP laminates, GFRP bars, mechanical anchorage plates, and concrete jacketing. Although similar retrofitting methods are increasingly adopted, detailed analyses in line with BS code provisions remain limited. The research addresses this gap through four-point bending tests, examining crack behaviour, failure modes, load–deflection behaviour, and comparisons between experimental results and analytical predictions based on BS code provisions. Five beams were used as controls and five beams used as the retrofitted beams. Beams A, B, C, and D shared a concrete compressive strength of 37.03 MPa, whereas beam E has a strength of 26.77 MPa. Tension reinforcement was varied between two 12 mm diameter bottom bars and three 12 mm bars. The ratio of the retrofitted beam to the unretrofitted beam ultimate loads were recorded as 140 %, 158 %, 154 %, 144 %, and 146 % for the beams A, B, C, D, and E respectively, indicating a significant increase as a result of the strengthening. A novel formula for estimating the flexural moment capacity of this first-time hybrid retrofitted beam is proposed and validated against experimental and analytical results. This novel combination of the hybrid retrofitting system significantly increased the flexural moment of the RC beam. The mean ratio of experimental to analytical moments is 0.94, with a variance of 0.00541, indicating strong agreement. The proposed novel hybrid retrofitting system and novel formula demonstrate high accuracy to the experimental results which helps to pre-empt the experimental moments before they are conducted. Also, the novel formula is suitable for application to beams with similar hybrid retrofitting configurations to significantly strengthen the flexural moment capacity of the RC beams.

Asian Journal of Advanced Research and ReportsVol. 19(9)
Openalex Percentile: Top 76%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental and Analytical Study on Structural Behaviour of RC Beams Retrofitted with a Hybrid System of CFRP, GFRP, Mas Plates, and Concrete Jacketing — Charles K. Kankam, Fredrick Ali Issifu, et al. · Asian Journal of Advanced Research and Reports (2025) | TGRS Research Map | TGRS