Development of Mobile‐Phase Buffers and Evaluation of Analytical Performance for HbA<sub>1c</sub> Assays

Hemoglobin A<sub>1c</sub> (HbA<sub>1c</sub>) plays a role in the diagnosis and assessment of glycemic control in patients with diabetes. However, few studies have focused on the preparation methods and analytical performance evaluation of different formulations of mobile-phase buffers for HbA<sub>1c</sub> assays. In this study, mobile-phase buffers of new formulations were prepared for the measurement of HbA<sub>1c</sub>. Following the Clinical and Laboratory Standards Institute (CLSI) guidelines, the analytical performance of newly developed mobile-phase buffers was evaluated. The CVs of the intra- and inter-assay precision were less than 0.94%, the RDs of accuracy were less than ± 3.00%, and the carryover was 0.00%. The measured HbA<sub>1c</sub> values were linear from 4.50% to 16.80% (26.00-160.00 mmol/mol). A comparison of newly developed and commercial mobile-phase buffers revealed that the Pearson regression equation was Y = 0.9862x + 0.0888 (R<sup>2</sup> = 0.9990), and the Bland-Altman mean difference between the two mobile-phase buffers was -0.02833% (95% CI: -0.1853% to 0.1278%). The chromatography column had a lifetime of over 7000 tests. The reference interval was 4.30%-6.30% (23.00-45.00 mmol/mol). Stability was acceptable within 24 months. The newly developed mobile-phase buffers demonstrated good analytical performance (i.e., precision, linearity, accuracy, carryover, reference interval, the number of chromatography column runs, and stability).

Authors

Institutions

Publication Details

Journal
Biomedical Chromatography
Published
2025-08-30
DOI
https://doi.org/10.1002/bmc.70136
Citations
1
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
1.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Mobile‐Phase Buffers and Evaluation of Analytical Performance for HbA1c Assays

Guangyun Zhang, Y.T. Zhang, Fen Yang, Zhikang Zou
1 citations
Biomedical Chromatography
Diabetes Management and Research
1.29
article

Development of Mobile‐Phase Buffers and Evaluation of Analytical Performance for HbA1c Assays

Guangyun Zhang, Y.T. Zhang, Fen Yang, Zhikang Zou
article en
1 citations

Abstract

Hemoglobin A<sub>1c</sub> (HbA<sub>1c</sub>) plays a role in the diagnosis and assessment of glycemic control in patients with diabetes. However, few studies have focused on the preparation methods and analytical performance evaluation of different formulations of mobile-phase buffers for HbA<sub>1c</sub> assays. In this study, mobile-phase buffers of new formulations were prepared for the measurement of HbA<sub>1c</sub>. Following the Clinical and Laboratory Standards Institute (CLSI) guidelines, the analytical performance of newly developed mobile-phase buffers was evaluated. The CVs of the intra- and inter-assay precision were less than 0.94%, the RDs of accuracy were less than ± 3.00%, and the carryover was 0.00%. The measured HbA<sub>1c</sub> values were linear from 4.50% to 16.80% (26.00-160.00 mmol/mol). A comparison of newly developed and commercial mobile-phase buffers revealed that the Pearson regression equation was Y = 0.9862x + 0.0888 (R<sup>2</sup> = 0.9990), and the Bland-Altman mean difference between the two mobile-phase buffers was -0.02833% (95% CI: -0.1853% to 0.1278%). The chromatography column had a lifetime of over 7000 tests. The reference interval was 4.30%-6.30% (23.00-45.00 mmol/mol). Stability was acceptable within 24 months. The newly developed mobile-phase buffers demonstrated good analytical performance (i.e., precision, linearity, accuracy, carryover, reference interval, the number of chromatography column runs, and stability).

Biomedical ChromatographyVol. 39(10)
United States Air Force (US), Air Force Engineering University (CN), Air Force General Hospital PLA (CN), Air Force Medical University (CN)
Openalex Percentile: Top 16%
Diabetes Management and Research
1.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.