Machine learning algorithms for voltage stability assessment in electrical distribution systems

Voltage instability poses a significant challenge by limiting power system operation and transmission capacity. Rapid detection and effective corrective actions are essential to prevent voltage collapse. However, traditional methods for assessing voltage security margins are computationally intensive and often impractical for real-time applications. This study addresses voltage stability assessment in power systems using machine learning (ML) to overcome the computational limitations of traditional methods. By employing Linear Regression (LR), Random Forest (RF), Gradient Boosting (GB), and Support Vector Machine (SVM), we predict Fast Voltage Stability Indices (FVSI) at nominal load as well as under varying loads (10-150%) in 15 kV Ethiopian distribution networks: a 35-bus Bata feeder system and a 53-bus Papyrus feeder system. RF and GB models achieved superior accuracy with R² values of 0.999 and 0.9998 respectively, significantly outperforming LR and SVM which exhibited substantial deviations. The GB model achieves the highest accuracy, with RMSE values of 0.0002 (53-bus) and 2.419e-05 (35-bus), while RF yields RMSE values of 0.0039 (53-bus) and 0.00120 (35-bus), demonstrating strong predictive performance. The FVSI threshold analysis revealed critical stability limits, with values approaching 1.0 indicating proximity to voltage collapse. The analysis identified buses 36, 32, and 21 in the 53-bus system (FVSI values: 0.087, 0.082, and 0.080) and buses 27 and 16 in the 35-bus system (FVSI values: 0.085 and 0.082) as critical instability risk points requiring immediate monitoring. These findings underscore the efficacy of ensemble methods for rapid voltage stability assessment and emphasize the need for targeted interventions in high-risk areas to bolster grid resilience in Ethiopian distribution networks.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-08-30
DOI
https://doi.org/10.1038/s41598-025-15791-2
Citations
3
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
2.19
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Machine learning algorithms for voltage stability assessment in electrical distribution systems

Mezigebu Getinet Yenealem, Tefera T. Yetayew, Girmaw Teshager Bitew, Teketay Mulu Beza et al.
3 citations
Scientific Reports
Power System Optimization and Stability
2.19
article

Machine learning algorithms for voltage stability assessment in electrical distribution systems

Mezigebu Getinet Yenealem, Tefera T. Yetayew, Girmaw Teshager Bitew, Teketay Mulu Beza, Molla Addisu Mossie
article en
3 citations

Abstract

Voltage instability poses a significant challenge by limiting power system operation and transmission capacity. Rapid detection and effective corrective actions are essential to prevent voltage collapse. However, traditional methods for assessing voltage security margins are computationally intensive and often impractical for real-time applications. This study addresses voltage stability assessment in power systems using machine learning (ML) to overcome the computational limitations of traditional methods. By employing Linear Regression (LR), Random Forest (RF), Gradient Boosting (GB), and Support Vector Machine (SVM), we predict Fast Voltage Stability Indices (FVSI) at nominal load as well as under varying loads (10-150%) in 15 kV Ethiopian distribution networks: a 35-bus Bata feeder system and a 53-bus Papyrus feeder system. RF and GB models achieved superior accuracy with R² values of 0.999 and 0.9998 respectively, significantly outperforming LR and SVM which exhibited substantial deviations. The GB model achieves the highest accuracy, with RMSE values of 0.0002 (53-bus) and 2.419e-05 (35-bus), while RF yields RMSE values of 0.0039 (53-bus) and 0.00120 (35-bus), demonstrating strong predictive performance. The FVSI threshold analysis revealed critical stability limits, with values approaching 1.0 indicating proximity to voltage collapse. The analysis identified buses 36, 32, and 21 in the 53-bus system (FVSI values: 0.087, 0.082, and 0.080) and buses 27 and 16 in the 35-bus system (FVSI values: 0.085 and 0.082) as critical instability risk points requiring immediate monitoring. These findings underscore the efficacy of ensemble methods for rapid voltage stability assessment and emphasize the need for targeted interventions in high-risk areas to bolster grid resilience in Ethiopian distribution networks.

Scientific ReportsVol. 15(1)
Bahir Dar University (ET), Adama Science and Technology University (ET)
Openalex Percentile: Top 11%
Power System Optimization and Stability
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.