Quantitative analysis of oligostyrenes using a charged aerosol detection: linearisation of quasi-linear calibration curves using power functions

The Charged Aerosol Detector (CAD) is a mass-based detector that is useful for solutes that cannot be detected by the UV/VIS detector due to no or weak chromophores. The CAD is being touted as a ‘Universal detector’, however, for the solute to be detected it must be less volatile than the mobile phase. The response of this detector is generally non-linear to concentration compared to the linear response of the UV detector making it difficult to undertake quantitative analysis. The aim of this study was to demonstrate the limitations of the CAD, using as an example, the analysis of a low molecular weight polystyrene that can be detected by both the UV and the CAD. Multiple power functions were applied to the response obtained from the CAD and it was determined for this study that a power function of 2.0 applied linearised the response in accordance to the UV detector derived response. This work shows the importance of finding the correct power function to be applied to the CAD to linearise the data and is dependent on the solute being detected. It is noted that this may be difficult when the solute being analysed cannot be detected by a detector, whose response is linear, such as, the UV detector. • Charged aerosol detection (CAD) yields non-linearity in the response-concentration response. • Power transformation of the raw response data output from the CAD can result in linearisation of the response-concentration relationship. • Optimisation of the power function is required for correct linearisation.

Authors

Institutions

Publication Details

Journal
Microchemical Journal
Published
2025-08-29
DOI
https://doi.org/10.1016/j.microc.2025.115105
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative analysis of oligostyrenes using a charged aerosol detection: linearisation of quasi-linear calibration curves using power functions

Arianne Soliven, Jake A. Cravino, Ross Andrew Shalliker, Feng Li et al.
2 citations
Microchemical Journal
Analytical Chemistry and Sensors
1.47
article

Quantitative analysis of oligostyrenes using a charged aerosol detection: linearisation of quasi-linear calibration curves using power functions

Arianne Soliven, Jake A. Cravino, Ross Andrew Shalliker, Feng Li, Christopher E. Karlsen
article en
2 citations

Abstract

The Charged Aerosol Detector (CAD) is a mass-based detector that is useful for solutes that cannot be detected by the UV/VIS detector due to no or weak chromophores. The CAD is being touted as a ‘Universal detector’, however, for the solute to be detected it must be less volatile than the mobile phase. The response of this detector is generally non-linear to concentration compared to the linear response of the UV detector making it difficult to undertake quantitative analysis. The aim of this study was to demonstrate the limitations of the CAD, using as an example, the analysis of a low molecular weight polystyrene that can be detected by both the UV and the CAD. Multiple power functions were applied to the response obtained from the CAD and it was determined for this study that a power function of 2.0 applied linearised the response in accordance to the UV detector derived response. This work shows the importance of finding the correct power function to be applied to the CAD to linearise the data and is dependent on the solute being detected. It is noted that this may be difficult when the solute being analysed cannot be detected by a detector, whose response is linear, such as, the UV detector. • Charged aerosol detection (CAD) yields non-linearity in the response-concentration response. • Power transformation of the raw response data output from the CAD can result in linearisation of the response-concentration relationship. • Optimisation of the power function is required for correct linearisation.

Microchemical JournalVol. 218
Universidad de la República de Uruguay (UY), Western Sydney University (AU)
Openalex Percentile: Top 16%
Analytical Chemistry and Sensors
1.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Quantitative analysis of oligostyrenes using a charged aerosol detection: linearisation of quasi-linear calibration curves using power functions — Arianne Soliven, Jake A. Cravino, et al. · Microchemical Journal (2025) | TGRS Research Map | TGRS