Compensated orthogonal spread codes for full parallel usage of multi-transducer ultrasonic testing systems in NDE

Introduction The use of multi-transducer methods and equipment is common in non- destructive testing. These systems and methods provide increased accuracy or even enable test cases that cannot be carried out with single transducer testing. On the downside, these systems significantly increase execution time when the evaluation of a single channel or evaluation of crosstalk to other channels is performed sequentially. As the number of individual channels increases, so does the execution time and the amount of data. This paper presents the theoretical integration and experimental validation of orthogonal spread code sequences for multi-transducer ultrasonic testing. Methods The custom-built, two-channel ultrasonic test system and the measurement setup using a 60 mm-wide rectangular specimen are shown. The cross-correlation properties of random binary, random Gaussian and Gold codes, known from GPS, are compared for the code selection. Results The Gold codes, the most promising set of codes, are experimentally investigated for suitability. Based on the results, upscaling potential of the method is presented based on a simulation using 9 code sequences summed with a random offset to a single array to replicate a 9-transducer setup. After compensating for the transfer function of the ultrasonic testing system, a localisation accuracy of less than 4 ns is achieved using a polynomial fit and a sampling interval of 8 ns. Discussion By incorporating this method into ultrasonic testing, measurement speed can be increased while stability and accuracy are improved.While codes with an amplitude close to the cross-correlation ratio will be difficult to detect, this method can be extended beyond 9 transducers for higher amplitudes, as long as the total amplitude does not exceed the maximum voltage limit of the electronic system.

Authors

Institutions

Publication Details

Journal
Frontiers in Acoustics
Published
2025-08-29
DOI
https://doi.org/10.3389/facou.2025.1620233
Primary Topic
Ultrasonics and Acoustic Wave Propagation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Compensated orthogonal spread codes for full parallel usage of multi-transducer ultrasonic testing systems in NDE

Sarah C. L. Fischer, Marius W. Schäfer, Giovanni Del Galdo
Frontiers in Acoustics
Ultrasonics and Acoustic Wave Propagation
article

Compensated orthogonal spread codes for full parallel usage of multi-transducer ultrasonic testing systems in NDE

Sarah C. L. Fischer, Marius W. Schäfer, Giovanni Del Galdo
article en

Abstract

Introduction The use of multi-transducer methods and equipment is common in non- destructive testing. These systems and methods provide increased accuracy or even enable test cases that cannot be carried out with single transducer testing. On the downside, these systems significantly increase execution time when the evaluation of a single channel or evaluation of crosstalk to other channels is performed sequentially. As the number of individual channels increases, so does the execution time and the amount of data. This paper presents the theoretical integration and experimental validation of orthogonal spread code sequences for multi-transducer ultrasonic testing. Methods The custom-built, two-channel ultrasonic test system and the measurement setup using a 60 mm-wide rectangular specimen are shown. The cross-correlation properties of random binary, random Gaussian and Gold codes, known from GPS, are compared for the code selection. Results The Gold codes, the most promising set of codes, are experimentally investigated for suitability. Based on the results, upscaling potential of the method is presented based on a simulation using 9 code sequences summed with a random offset to a single array to replicate a 9-transducer setup. After compensating for the transfer function of the ultrasonic testing system, a localisation accuracy of less than 4 ns is achieved using a polynomial fit and a sampling interval of 8 ns. Discussion By incorporating this method into ultrasonic testing, measurement speed can be increased while stability and accuracy are improved.While codes with an amplitude close to the cross-correlation ratio will be difficult to detect, this method can be extended beyond 9 transducers for higher amplitudes, as long as the total amplitude does not exceed the maximum voltage limit of the electronic system.

Frontiers in AcousticsVol. 3
Technische Universität Ilmenau (DE), Fraunhofer Institute for Integrated Circuits (DE), Fraunhofer Institute for Nondestructive Testing (DE)
Fraunhofer-Gesellschaft
Openalex Percentile: Top 74%
Ultrasonics and Acoustic Wave Propagation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.