Evaluating scintigraphic dyssynchrony as radiomic parameters for dynamic laminar and turbulent fluids in compartmental phantom systems: A signal processing study

Abstract Introduction : Radiomics quantify radiological data to correlate with clinical findings. Dyssynchrony, a proposed radiomic parameter measured via phase images, reflects the temporal discoordination of ventricular contraction, which can impair overall cardiac efficiency. This study assessed the consistency and reliability of dyssynchrony in laminar and turbulent flow compartments under varying image acquisition. It also evaluated the relationship between dyssynchrony and fluid dynamics alterations. Methods : The dataset included 64 dynamic images using gamma camera (128,000 frames) generated using an in-home phantom, representing combinations of flow velocity, count, and frame rates. Phase and amplitude images were generated and analyzed to calculate synchrony, entropy, approximate entropy (ApEn), and bounded-ApEn for different rotation directions. Entropy values were examined under parameter changes, with comparisons using Pearson’s test, ANOVA, logistic regression, and receiver operating characteristic (ROC) analysis. Results : Images were categorized by activity concentrations: Group 1 (37 MBq), Group 2 (29.5 MBq), and Group 3 (18.5 MBq). Group 1 showed a strong negative correlation between entropy and frame rates (r = −0.991, p < 0.001), while Group 3 displayed positive correlations between frame rate, ApEn, gray count, and pixel count. Logistic regression predicted turbulence (AUC = 0.93) and direction (AUC = 0.96) using bounded-ApEn. Regression analysis indicated ApEn and bounded-ApEn significantly predicted vortex parameters (R² = 93%). Conclusion : Dyssynchrony metrics, including entropy, ApEn, and bounded-ApEn, demonstrated consistent measurements across varying conditions. These findings highlight their potential for enhancing diagnostic accuracy and guiding personalized therapeutic strategies for conditions influenced by blood flow patterns

Authors

Institutions

Publication Details

Journal
Polish Journal of Medical Physics And Engineering
Published
2025-08-28
DOI
https://doi.org/10.2478/pjmpe-2025-0026
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating scintigraphic dyssynchrony as radiomic parameters for dynamic laminar and turbulent fluids in compartmental phantom systems: A signal processing study

Ahmad Alenezi
Polish Journal of Medical Physics And Engineering
Radiation Dose and Imaging
article

Evaluating scintigraphic dyssynchrony as radiomic parameters for dynamic laminar and turbulent fluids in compartmental phantom systems: A signal processing study

Ahmad Alenezi
article en

Abstract

Abstract Introduction : Radiomics quantify radiological data to correlate with clinical findings. Dyssynchrony, a proposed radiomic parameter measured via phase images, reflects the temporal discoordination of ventricular contraction, which can impair overall cardiac efficiency. This study assessed the consistency and reliability of dyssynchrony in laminar and turbulent flow compartments under varying image acquisition. It also evaluated the relationship between dyssynchrony and fluid dynamics alterations. Methods : The dataset included 64 dynamic images using gamma camera (128,000 frames) generated using an in-home phantom, representing combinations of flow velocity, count, and frame rates. Phase and amplitude images were generated and analyzed to calculate synchrony, entropy, approximate entropy (ApEn), and bounded-ApEn for different rotation directions. Entropy values were examined under parameter changes, with comparisons using Pearson’s test, ANOVA, logistic regression, and receiver operating characteristic (ROC) analysis. Results : Images were categorized by activity concentrations: Group 1 (37 MBq), Group 2 (29.5 MBq), and Group 3 (18.5 MBq). Group 1 showed a strong negative correlation between entropy and frame rates (r = −0.991, p < 0.001), while Group 3 displayed positive correlations between frame rate, ApEn, gray count, and pixel count. Logistic regression predicted turbulence (AUC = 0.93) and direction (AUC = 0.96) using bounded-ApEn. Regression analysis indicated ApEn and bounded-ApEn significantly predicted vortex parameters (R² = 93%). Conclusion : Dyssynchrony metrics, including entropy, ApEn, and bounded-ApEn, demonstrated consistent measurements across varying conditions. These findings highlight their potential for enhancing diagnostic accuracy and guiding personalized therapeutic strategies for conditions influenced by blood flow patterns

Polish Journal of Medical Physics And EngineeringVol. 31(3)
Kuwait University (KW)
Kuwait University
Openalex Percentile: Top 68%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluating scintigraphic dyssynchrony as radiomic parameters for dynamic laminar and turbulent fluids in compartmental phantom systems: A signal processing study — Ahmad Alenezi · Polish Journal of Medical Physics And Engineering (2025) | TGRS Research Map | TGRS