Comparative Analysis of Diagnostic Performance Between Elastography and AI-Based S-Detect for Thyroid Nodule Detection
<b>Background/Objectives:</b> Elastography is a non-invasive imaging technique that assesses tissue stiffness and elasticity. This study aimed to evaluate the diagnostic performance and clinical utility of elastography and S-detect in distinguishing benign from malignant thyroid nodules. S-detect (RS85) is a deep learning-based computer-aided diagnosis (DL-CAD) software that analyzes grayscale ultrasound 2D images to evaluate the morphological characteristics of thyroid nodules, providing a visual guide to the likelihood of malignancy. <b>Method:</b> This retrospective study included 159 patients (61 male and 98 female) aged 30-83 years (56.14 ± 11.35) who underwent thyroid ultrasonography between January 2023 and June 2024. All the patients underwent elastography, S-detect analysis, and fine needle aspiration cytology (FNAC). Malignancy status was determined based on the FNAC findings, and the diagnostic performance of the elasticity contrast index (ECI), S-detect, and evaluations by a radiologist were assessed. Based on the FNAC results, 101 patients (63.5%) had benign nodules and 58 patients (36.5%) had malignant nodules. <b>Results:</b> Radiologist interpretation demonstrated the highest diagnostic accuracy (area under the curve 89%), with a sensitivity of 98.28%, specificity of 79.21%, positive predictive value (PPV) of 73.1%, and negative predictive value (NPV) of 98.8%. The elasticity contrast index showed an accuracy of 85%, sensitivity of 87.93%, specificity of 81.19%, PPV of 72.9%, and NPV of 92.1%. S-detect yielded the lowest accuracy at 78%, with a sensitivity of 87.93%, specificity of 68.32%, PPV of 61.4%, and NPV of 90.8%. <b>Conclusions:</b> These findings offer valuable insights into the comparative diagnostic utility of elastography and AI-based S-detect for thyroid nodules in clinical practice. Although limited by its single-center design and sample size, which potentially limits the generalization of the results, the controlled environment ensured consistency and minimized confounding variables.
Authors
- Jee-Yeun Park
- Sung-Hee Yang
Institutions
- Catholic University of Pusan (KR)
- Inje University Haeundae Paik Hospital (KR)
Publication Details
- Journal
- Diagnostics
- Published
- 2025-08-29
- DOI
- https://doi.org/10.3390/diagnostics15172191
- Primary Topic
- Thyroid Cancer Diagnosis and Treatment
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Research Foundation
- Catholic University of Pusan
- National Research Foundation of Korea